Prevention of the stapler line leak after laparoscopic sleeve gastrectomy in patients with morbid obesity

O. O. Kalashnikov, O. Yu. Usenko, I. M. Todurov, S. V. Kosiukhno

Modern medical technology · 2024

DOI: 10.14739/mmt.2024.1.298490 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Modern medical technology, 2024. Verfasst von O. O. Kalashnikov und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Obesity has become a global pandemic, leading to increased morbidity and mortality among patients, both young and old. Bariatric surgery is the most effective method for treating pathological obesity. Laparoscopic sleeve gastrectomy has become the most popular bariatric procedure worldwide. However, staple line leak is the most dreaded postoperative complication following laparoscopic sleeve gastrectomy. In order to reduce the incidence of this complication, most surgeons prefer to reinforce the staple line. However, there is no compelling evidence to suggest that peritonealization of the staple line or the use of coated stapler cartridges during laparoscopic sleeve gastrectomy reduces the risk of leakage. Therefore, we conducted a retrospective analysis to assess the impact of coated stapler cartridges on preventing staple line leaks. The aim of the study. To evaluate the effect of using stapler with coating on preventing staple line leaks during laparoscopic sleeve gastrectomy in patients with morbid obesity. Materials and methods. This was a retrospective analysis of 45 patients who underwent laparoscopic sleeve gastrectomy using endostapler from Medtronic (Endo GIA™) without additional reinforcement (Group I) and 46 patients who underwent a similar procedure using endostapler from Medtronic (Endo GIA™) stapler with coating (Group II). Both patient groups were homogeneous in terms of demographic characteristics. We compared the duration of surgery, intraoperative blood loss, length of hospital stay, and the incidence of staple line leak.

Results

The incidence of staple line leak was statistically significantly higher in Group I compared to Group II (5/40 vs. 0/46; χ2 = 5.4, p = 0.021). This resulted in a statistically significant increase in blood loss (U = 706; p = 0.006), prolonged total operation time (U = 310; p = 0.001), and extended postoperative hospital stay (U = 245; p = 0.001) in Group I. The median time to healing of the leak was 32 [20; 59] days. No patient died.

Conclusions

Using the endostapler with purple cartridges with coating from Medtronic during laparoscopic sleeve gastrectomy significantly reduced postoperative leak rate and significantly decreased postoperative hospital stay.

Zitieren

APA

Kalashnikov, O. O., Usenko, O. Y., Todurov, I. M., & Kosiukhno, S. V. (2024). Prevention of the stapler line leak after laparoscopic sleeve gastrectomy in patients with morbid obesity. Modern medical technology. https://doi.org/10.14739/mmt.2024.1.298490

Vancouver

Kalashnikov OO, Usenko OY, Todurov IM, Kosiukhno SV. Prevention of the stapler line leak after laparoscopic sleeve gastrectomy in patients with morbid obesity. Modern medical technology. 2024. doi:10.14739/mmt.2024.1.298490