EUVIMEDEUVIMED entdecken
Crossref

Treatment of a staple-line leak after laparoscopic sleeve gastrectomy using an esophagoduodenal Niti-S Mega-stent

F. Vara-Luiz, I. Mendes, G. Nunes, C. Oliveira, C. Afonso, A. Pascoal, P. Lages, S. Onofre, J. Fonseca

Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S193

DOI: 10.1055/s-0044-1783124 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von F. Vara-Luiz und 8 weiteren Autor:innen. Die Arbeit nennt 5 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Text Laparoscopic sleeve gastrectomy (LSG) has become the most frequently performed bariatric surgery. Staple-line leak occur in 5.5% of cases and is associated with significant morbidity. A 56-year-old female with class 3 obesity was admitted 2 weeks after LSG due to fever and abdominal pain. Upper endoscopy showed a 10-mm leak at the esophago-gastric junction with contrast extravasation. After 0,038’’ guidewire placement through the proximal jejunum, a Niti-S Mega-Stent 28x230mm was deployed under fluoroscopy. Oral nutrition was started uneventfully. After 8 weeks the stent was removed, and granulation tissue was observed with no contrast extravasation. Endoluminal stenting is commonly used for staple-line leaks after LSG. Mega-stent offers complete bridging between esophagus and the duodenum, overcoming self-expandable metal stents’ limitations and increasing treatment success [ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ]. Video http://data.process.y-congress.com/ScientificProcess/Data//106/474/1197/3bcfd7d9-43eb-4162-ba2a-5c12a5038506/Uploads/13821_Mega-stent(1).mp4 Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Vara-Luiz, F., Mendes, I., Nunes, G., Oliveira, C., Afonso, C., Pascoal, A., Lages, P., Onofre, S., & Fonseca, J. (2024). Treatment of a staple-line leak after laparoscopic sleeve gastrectomy using an esophagoduodenal Niti-S Mega-stent. Endoscopy, 56(S 02 S 02), S193. https://doi.org/10.1055/s-0044-1783124

Vancouver

Vara-Luiz F, Mendes I, Nunes G, Oliveira C, Afonso C, Pascoal A, et al. Treatment of a staple-line leak after laparoscopic sleeve gastrectomy using an esophagoduodenal Niti-S Mega-stent. Endoscopy. 2024;56(S 02 S 02):S193. doi:10.1055/s-0044-1783124

BibTeX
@article{VaraLuiz2024,
  author = {Vara-Luiz, F. and Mendes, I. and Nunes, G. and Oliveira, C. and Afonso, C. and Pascoal, A. and Lages, P. and Onofre, S. and Fonseca, J.},
  title = {Treatment of a staple-line leak after laparoscopic sleeve gastrectomy using an esophagoduodenal Niti-S Mega-stent},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S193},
  doi = {10.1055/s-0044-1783124}
}
Kostenlos starten →