EUVIMEDEUVIMED entdecken
FallberichtOpen Access

Transcatheter Closure of Ruptured Sinus of Valsalva Aneurysm with Double-Disc Perimembranous VSD Occluder in Man with Mechanical Aortic Valve

Liang Tang, Sheng-Hua Zhou, Zhen-Fei Fang

Texas Heart Institute Journal · 2019-06 · 46 (3) · 211-214

DOI: 10.14503/thij-17-6215 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Texas Heart Institute Journal, 2019-06. Verfasst von Liang Tang und 2 weiteren Autor:innen. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Septal Occluder Device, Sinus of Valsalva. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 11 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sinus of Valsalva aneurysm, a rare cardiac anomaly, can be life-threatening if it ruptures. Transcatheter closure has emerged as an effective alternative to surgical management; however, it has rarely been reported in patients with previous mechanical aortic valve replacements. We describe the case of a 45-year-old man who presented with a ruptured aneurysm of the noncoronary sinus of Valsalva 14 years after the implantation of a mechanical aortic valve. The ruptured aneurysm was closed by transcatheter means with use of a double-disc perimembranous ventricular septal defect occluder. The patient remained asymptomatic one year after the procedure. Our case suggests that transcatheter closure with use of this type of occluder is a viable method for successfully repairing ruptured sinus of Valsalva aneurysms in patients who have mechanical aortic valves.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisSeptal Occluder DeviceSinus of ValsalvaAortic RuptureAortic ValveAortic Valve StenosisAortographyCardiac CatheterizationEchocardiographyHumansMaleMiddle AgedVascular Surgical Procedures

Stichwörter der Autor:innen

Aneurysm, ruptured/pathology/therapyballoon occlusion/instrumentationcardiac surgical procedures/methodsheart aneurysm/therapyheart valve prosthesis implantation/methodsseptal occluder devicesinus of Valsalva/pathologytreatment outcome

Zitieren

APA

Tang, L., Zhou, S. H., & Fang, Z. F. (2019). Transcatheter Closure of Ruptured Sinus of Valsalva Aneurysm with Double-Disc Perimembranous VSD Occluder in Man with Mechanical Aortic Valve. Texas Heart Institute Journal, 46(3), 211-214. https://doi.org/10.14503/thij-17-6215

Vancouver

Tang L, Zhou SH, Fang ZF. Transcatheter Closure of Ruptured Sinus of Valsalva Aneurysm with Double-Disc Perimembranous VSD Occluder in Man with Mechanical Aortic Valve. Texas Heart Institute Journal. 2019;46(3):211-214. doi:10.14503/thij-17-6215

BibTeX
@article{Tang2019,
  author = {Tang, Liang and Zhou, Sheng-Hua and Fang, Zhen-Fei},
  title = {Transcatheter Closure of Ruptured Sinus of Valsalva Aneurysm with Double-Disc Perimembranous VSD Occluder in Man with Mechanical Aortic Valve},
  journal = {Texas Heart Institute Journal},
  year = {2019},
  volume = {46},
  number = {3},
  pages = {211--214},
  doi = {10.14503/thij-17-6215}
}
Kostenlos starten →