EUVIMEDEUVIMED entdecken
Fallbericht

Successful Transcatheter Aortic Valve Replacement in a Patient with Previous Aortic Coarctation Bypass Graft: A Case Report

Georgios E Papadopoulos iD, Ilias Ninios, Konstantinos Papazoglou, Vlasis Ninios

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70354 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Georgios E Papadopoulos und 3 weiteren Autor:innen. Beteiligte Einrichtung: Interbalkan European Medical Center, Thessaloniki, Greece. Hauptthemen laut MEDLINE: Aortic Valve Stenosis, Transcatheter Aortic Valve Replacement, Aortic Coarctation, Blood Vessel Prosthesis Implantation. Die Arbeit nennt 7 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Transfemoral (TF) TAVR can be challenging in patients with prior aortic coarctation repair and bypass grafts due to extreme tortuosity. Case A 74‐year‐old man with severe symptomatic aortic stenosis and a prior left‐subclavian‐to‐descending aortic bypass presented for TAVR. CT showed a large, calcified annulus (perimeter‐derived diameter 27.6 mm; area 573.7 mm²) and a serpiginous, calcified bypass graft. After initial failure to advance the system through the graft, we pre‐shaped a Lunderquist wire with an acute bend ~40 cm from the tip to redirect the delivery vector. A 27.5‐mm balloon‐expandable MyVal was then advanced and deployed uneventfully, with no paravalvular leak.

Conclusion

Intentional pre‐shaping of a stiff wire can facilitate TF device traversal across aorto–subclavian bypass grafts with severe tortuosity, enabling safe, precise deployment when TF remains the preferred route.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Valve StenosisTranscatheter Aortic Valve ReplacementAortic CoarctationBlood Vessel Prosthesis ImplantationAortic ValveCoronary Artery BypassHumansAgedMaleTreatment OutcomeHeart Valve ProsthesisSeverity of Illness IndexProsthesis DesignBlood Vessel ProsthesisComputed Tomography AngiographyAortography

Stichwörter der Autor:innen

aortic coarctationaortic stenosisballoon‐expandable valvelunderquist wiretranscatheter aortic valve replacement

Autor:innen und Institutionen

  • Interbalkan European Medical Center, Thessaloniki, Greece.

ORCID-Profile: Georgios E Papadopoulos

Zitieren

APA

Papadopoulos, G. E., Ninios, I., Papazoglou, K., & Ninios, V. (2026). Successful Transcatheter Aortic Valve Replacement in a Patient with Previous Aortic Coarctation Bypass Graft: A Case Report. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70354

Vancouver

Papadopoulos GE, Ninios I, Papazoglou K, Ninios V. Successful Transcatheter Aortic Valve Replacement in a Patient with Previous Aortic Coarctation Bypass Graft: A Case Report. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70354

BibTeX
@article{Papadopoulos2026,
  author = {Papadopoulos, Georgios E and Ninios, Ilias and Papazoglou, Konstantinos and Ninios, Vlasis},
  title = {Successful Transcatheter Aortic Valve Replacement in a Patient with Previous Aortic Coarctation Bypass Graft: A Case Report},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70354}
}
Kostenlos starten →