Stability and Instrumentation Stresses Among Sacropelvic Fixation Techniques With Novel Porous Fusion/Fixation Implants: A Finite Element Study
International Journal of Spine Surgery · 2023-08 · 17 (4) · 598-606
DOI: 10.14444/8481 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Spine Surgery, online erschienen am 17.07.2023. Verfasst von Matteo Panico und 8 weiteren Autor:innen. Beteiligte Einrichtung: IRCCS Istituto Ortopedico Galeazzi, Milan, Italy. Die Arbeit wurde bisher 8-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND: Sacropelvic fixation is frequently combined with thoracolumbar instrumentation for correcting spinal deformities. This study aimed to characterize sacropelvic fixation techniques using novel porous fusion/fixation implants (PFFI). METHODS: Three T10-pelvis finite element models were created: (1) pedicle screws and rods in T10-S1, PFFI bilaterally in S2 alar-iliac (S2AI) trajectory; (2) fixation in T10-S1, PFFI bilaterally in S2AI trajectory, triangular implants bilaterally above the PFFI in a sacro-alar-iliac trajectory (PFFI-IFSAI); and (3) fixation in T10-S1, PFFI bilaterally in S2AI trajectory, PFFI in sacro-alar-iliac trajectory stacked cephalad to those in S2AI position (2-PFFI). Models were loaded with pure moments of 7.5 Nm in flexion-extension, lateral bending, and axial rotation. Outputs were compared against 2 baseline models: (1) pedicle screws and rods in T10-S1 (PED), and (2) pedicle screws and rods in T10-S1, and S2AI screws. RESULTS: PFFI and S2AI resulted in similar L5-S1 motion; adding another PFFI per side (2-PFFI) further reduced this motion. Sacroiliac joint (SIJ) motion was also similar between PFFI and S2AI; PFFI-IFSAI and 2-PFFI demonstrated a further reduction in SIJ motion. Additionally, PFFI reduced max stresses on S1 pedicle screws and on implants in the S2AI position. CONCLUSION: The study shows that supplementing a long construct with PFFI increases the stability of the L5-S1 and SIJ and reduces stresses on the S1 pedicle screws and implants in the S2AI position. CLINICAL RELEVANCE: The findings suggest a reduced risk of pseudarthrosis at L5-S1 and screw breakage. Clinical studies may be performed to demonstrate applicability to patient outcomes. LEVEL OF EVIDENCE: Not applicable (basic science study).
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy.
- Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy.
- SI-BONE, Inc., Santa Clara, CA, USA.
- DISC Sports and Spine Center, Newport Beach, CA, USA.
- Department of Orthopaedic Surgery, University of Minnesota, Minneapolis, MN, USA.
- Spine Center, Schulthess Clinic, Zurich, Switzerland fabio.galbusera@kws.ch.
Zitieren
APA
Panico, M., Chande, R. D., Lindsey, D. P., Mesiwala, A., Polly, D. W., Villa, T., Yerby, S. A., Brayda-Bruno, M., & Galbusera, F. (2023). Stability and Instrumentation Stresses Among Sacropelvic Fixation Techniques With Novel Porous Fusion/Fixation Implants: A Finite Element Study. International Journal of Spine Surgery, 17(4), 598-606. https://doi.org/10.14444/8481
Vancouver
Panico M, Chande RD, Lindsey DP, Mesiwala A, Polly DW, Villa T, et al. Stability and Instrumentation Stresses Among Sacropelvic Fixation Techniques With Novel Porous Fusion/Fixation Implants: A Finite Element Study. International Journal of Spine Surgery. 2023;17(4):598-606. doi:10.14444/8481
BibTeX
@article{Panico2023,
author = {Panico, Matteo and Chande, Ruchi D and Lindsey, Derek P and Mesiwala, Ali and Polly, David W and Villa, Tomaso and Yerby, Scott A and Brayda-Bruno, Marco and Galbusera, Fabio},
title = {Stability and Instrumentation Stresses Among Sacropelvic Fixation Techniques With Novel Porous Fusion/Fixation Implants: A Finite Element Study},
journal = {International Journal of Spine Surgery},
year = {2023},
volume = {17},
number = {4},
pages = {598--606},
doi = {10.14444/8481}
}
EUVIMED