EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Proposal of National Diagnostic Reference Levels for Selected General Radiography Procedures in Ghana

Daniel Abbeyquaye, Stephen Inkoom, Shirazu Issahaku, Theresa Bebaaku Dery, David Ebo Anderson, Van Wellington Elloh

Journal of Radiation Protection and Research · 30.06.2026 · 51 (2) · 67-77

DOI: 10.14407/jrpr.2025.00262 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Radiation Protection and Research, erschienen am 30.06.2026. Verfasst von Daniel Abbeyquaye und 5 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: University of Ghana BANGA-Africa.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Diagnostic reference levels (DRLs) are integral to optimizing the patient dose in diagnostic radiology, and yet data for low- and middle-income countries are limited. Here, we propose the first Ghanan national DRLs (NDRLs) for selected radiographic procedures, aiming to enhance dose standardization and patient safety.Materials and Methods: A nationwide cross-sectional dosimetry survey of 41 radiologic systems reviewed eight frequently performed examinations across 7,643 adult patients. An indirect method based on X-ray tube output measurements and technical exposure factors was used to evaluate entrance surface dose in those patients. The 75th percentile of each facility’s median entrance surface dose for each examination/projection was proposed as the NDRL. The resulting NDRLs were compared with international NDRLs to assess dose variability and levels against global standards.Results and Discussion: The proposed NDRLs are chest posterior–anterior (PA, 0.36 mGy), chest lateral (LAT, 0.97 mGy), pelvis anterior–posterior (AP, 2.77 mGy), skull AP/PA (2.00 mGy), skull LAT (1.75 mGy), lumbar spine AP (3.64 mGy), lumbar spine LAT (7.12 mGy), and abdomen AP (2.44 mGy). Although doses sometimes varied across facilities, particularly in high-attenuation procedures such as lumbar spine LAT, the chest PA values aligned closely with the international references. The results highlight the need to optimize imaging protocols and equipment performance and to invest in modern imaging equipment with advanced dose reduction capabilities to augment patient dose optimization initiatives in Ghana.

Conclusion

We propose Ghana’s first NDRLs for general radiography procedures to guide national dose optimization efforts. Implementing these NDRLs would help to standardize imaging protocols, minimize patient exposures, and bolster diagnostic efficacy. Ongoing collaboration between regulatory authorities, healthcare facilities, and researchers is essential to implement and ensure sustained improvements in patient radiologic safety.

Förderung

  • University of Ghana BANGA-Africa

Zitieren

APA

Abbeyquaye, D., Inkoom, S., Issahaku, S., Dery, T. B., Anderson, D. E., & Elloh, V. W. (2026). Proposal of National Diagnostic Reference Levels for Selected General Radiography Procedures in Ghana. Journal of Radiation Protection and Research, 51(2), 67-77. https://doi.org/10.14407/jrpr.2025.00262

Vancouver

Abbeyquaye D, Inkoom S, Issahaku S, Dery TB, Anderson DE, Elloh VW. Proposal of National Diagnostic Reference Levels for Selected General Radiography Procedures in Ghana. Journal of Radiation Protection and Research. 2026;51(2):67-77. doi:10.14407/jrpr.2025.00262

BibTeX
@article{Abbeyquaye2026,
  author = {Abbeyquaye, Daniel and Inkoom, Stephen and Issahaku, Shirazu and Dery, Theresa Bebaaku and Anderson, David Ebo and Elloh, Van Wellington},
  title = {Proposal of National Diagnostic Reference Levels for Selected General Radiography Procedures in Ghana},
  journal = {Journal of Radiation Protection and Research},
  year = {2026},
  volume = {51},
  number = {2},
  pages = {67--77},
  doi = {10.14407/jrpr.2025.00262}
}
Kostenlos starten →