EUVIMEDSkopri EUVIMED
Crossref

Effect of a Non-polymer Titanium Dioxide Thin Film-Coated Stent with Heparin in a Porcine Coronary Restenosis Model

Kyung Seob Lim, Myung Ho Jeong, In Ho Bae, Jun-Kyu Park, Dae Sung Park, Jae Won Shim, Han Byual Kim, Mi Rim Jin, Hyun Kuk Kim, Sung Soo Kim, Min Chul Kim, Doo Sun Sim and 3 more

Clinical & Experimental Thrombosis and Hemostasis · 2017

DOI: 10.14345/ceth.17005 ↗

At a glance

Journal article in Clinical & Experimental Thrombosis and Hemostasis, 2017. Written by Kyung Seob Lim and 14 co-authors. Cited 1 times so far (Crossref); 28 references. Funded by: Korean Society on Thrombosis and Hemosatsis, National Research Foundation, Ministry of Education, Science and Technology.

AstrattDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Purpose

The aim of this study was to examine the effect of non-polymer titanium dioxide (TiO2) thin filmcoated stents modified with heparin in a porcine coronary overstretch restenosis model.

Methods

Pigs were randomized into three groups in which either TiO2 film-heparin coated stent (THS, n = 12), zotarolimus-eluting stent with polymer (ZES, n = 12), or bare metal stent (BMS, n = 12) was placed in a coronary artery (18 pigs, 12 coronaries in each group).Histopathologic analysis was performed at 28 days after stenting.

Results

There was no significant difference in injury score among the three groups.There were significant differences in neointima area (2.9 ± 0.85 mm 2 in the THS group vs. 2.8 ± 0.10 mm 2 in the ZES group vs. 3.3 ± 0.58 mm 2 in the BMS group, P< 0.05), fibrin score (0.0 [range 0.0 to 1.0] in the THS group vs. 2.0 [range 2.0 to 2.0] in the ZES group vs. 0.5 [range 0.0 to 2.0] in the BMS group, P< 0.0001), and inflammation score (1.0 [range 0.0-1.0] in the THS group vs. 1.0 [range 1.0 to 2.0] in the ZES group vs. 1.0 [range 0.75 to 1.0] in the BMS group, P< 0.0001) among the three groups.In-stent restenosis rate, as measured by micro computed tomography, demonstrated similar percent area values upon histology analysis (57.7 ± 13.14% in the THS group vs. 58.7 ± 16.44% in the ZES group 64.8 ± 8.56% in the BMS group, P< 0.05).

Conclusion

THS is more effective in reducing neointima formation compared to BMS.Moreover, the neointima suppressive effect of THS exceeds that of commercial ZES, with lower fibrin and inflammation scores in a porcine coronary restenosis model.

Funding

  • Korean Society on Thrombosis and Hemosatsis
  • National Research Foundation
  • Ministry of Education, Science and Technology

Cite

APA

Lim, K. S., Jeong, M. H., Bae, I. H., Park, J., Park, D. S., Shim, J. W., Kim, H. B., Jin, M. R., Kim, H. K., Kim, S. S., Kim, M. C., Sim, D. S., Hong, Y. J., Kim, J. H., & Ahn, Y. (2017). Effect of a Non-polymer Titanium Dioxide Thin Film-Coated Stent with Heparin in a Porcine Coronary Restenosis Model. Clinical & Experimental Thrombosis and Hemostasis. https://doi.org/10.14345/ceth.17005

Vancouver

Lim KS, Jeong MH, Bae IH, Park J, Park DS, Shim JW, et al. Effect of a Non-polymer Titanium Dioxide Thin Film-Coated Stent with Heparin in a Porcine Coronary Restenosis Model. Clinical & Experimental Thrombosis and Hemostasis. 2017. doi:10.14345/ceth.17005

BibTeX
@article{Lim2017,
  author = {Lim, Kyung Seob and Jeong, Myung Ho and Bae, In Ho and Park, Jun-Kyu and Park, Dae Sung and Shim, Jae Won and Kim, Han Byual and Jin, Mi Rim and Kim, Hyun Kuk and Kim, Sung Soo and Kim, Min Chul and Sim, Doo Sun and Hong, Young Joon and Kim, Ju Han and Ahn, Youngkeun},
  title = {Effect of a Non-polymer Titanium Dioxide Thin Film-Coated Stent with Heparin in a Porcine Coronary Restenosis Model},
  journal = {Clinical & Experimental Thrombosis and Hemostasis},
  year = {2017},
  doi = {10.14345/ceth.17005}
}
Start for free →