EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Fabrication of a Patient-Customized Helmet with a Three-Dimensional Printer for Radiation Therapy of Scalp

Se An Oh, Chang Min Lee, Min Woo Lee, Yeong Seok Lee, Gyu Hwan Lee, Seong Hoon Kim, Sung Kyu Kim, Jae Won Park, Ji Woon Yea

Progress in Medical Physics · 2017

DOI: 10.14316/pmp.2017.28.3.100 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Progress in Medical Physics, 2017. Verfasst von Se An Oh und 8 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Research Foundation of Korea, Korea Foundation for the Advancement of Science and Creativity.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Corresponding author Ji Woon Yea (yjw1160@ynu.ac.kr) Tel: 82-53-620-3371 Fax: 82-53-624-3599 The purpose of the present study was to develop and evaluate patient-customized helmets with a three-dimensional (3D) printer for radiation therapy of malignant scalp tumors. Computed tomography was performed in a case an Alderson RANDO phantom without bolus (Non_Bolus), in a case with a dental wax bolus on the scalp (Wax_Bolus), and in a case with a patient-customized helmet fabricated using a 3D printer (3D Printing_Bolus); treatment plans for each of the 3 cases were compared. When wax bolus was used to fabricate a bolus, a drier was used to apply heat to the bolus to make the helmet. 3-matic (Materialise) was used for modeling and polyamide 12 (PA12) was used as a material, 3D Printing bolus was fabricated using a HP JET Fusion 3D 4200. The average Hounsfield Unit (HU) for the Wax_Bolus was −100, and that of the 3D Printing_Bolus was −10. The average radiation doses to the normal brain with the Non_Bolus, Wax_Bolus, and 3D Printing_Bolus methods were 36.3%, 40.2%, and 36.9%, and the minimum radiation dose were 0.9%, 1.6%, 1.4%, respectively. The organs at risk dose were not significantly difference. However, the 95% radiation doses into the planning target volume (PTV) were 61.85%, 94.53%, and 97.82%, and the minimum doses were 0%, 77.1%, and 82.8%, respectively. The technique used to fabricate patient-customized helmets with a 3D printer for radiation therapy of malignant scalp tumors is highly useful, and is expected to accurately deliver doses by reducing the air gap between the patient and bolus.

Förderung

  • National Research Foundation of Korea
  • Korea Foundation for the Advancement of Science and Creativity

Zitieren

APA

Oh, S. A., Lee, C. M., Lee, M. W., Lee, Y. S., Lee, G. H., Kim, S. H., Kim, S. K., Park, J. W., & Yea, J. W. (2017). Fabrication of a Patient-Customized Helmet with a Three-Dimensional Printer for Radiation Therapy of Scalp. Progress in Medical Physics. https://doi.org/10.14316/pmp.2017.28.3.100

Vancouver

Oh SA, Lee CM, Lee MW, Lee YS, Lee GH, Kim SH, et al. Fabrication of a Patient-Customized Helmet with a Three-Dimensional Printer for Radiation Therapy of Scalp. Progress in Medical Physics. 2017. doi:10.14316/pmp.2017.28.3.100

BibTeX
@article{Oh2017,
  author = {Oh, Se An and Lee, Chang Min and Lee, Min Woo and Lee, Yeong Seok and Lee, Gyu Hwan and Kim, Seong Hoon and Kim, Sung Kyu and Park, Jae Won and Yea, Ji Woon},
  title = {Fabrication of a Patient-Customized Helmet with a Three-Dimensional Printer for Radiation Therapy of Scalp},
  journal = {Progress in Medical Physics},
  year = {2017},
  doi = {10.14316/pmp.2017.28.3.100}
}
Kostenlos starten →