Evaluation of dosimetric parameters in three volumetric modulated arc therapy regimens for hippocampal and scalp sparing in whole-brain radiation therapy
Frontiers in Physics · 08.07.2026 · 14
DOI: 10.3389/fphy.2026.1843325 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Physics, online erschienen am 08.07.2026. Verfasst von Huaqu Zeng und 5 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
To evaluate the dosimetric performance of three Volumetric Modulated Arc Therapy (VMAT) techniques with different beam arrangements—Coplanar Partial-Field VMAT (PF-VMAT), Non-Coplanar VMAT (NC-VMAT), and Coplanar Whole-Field VMAT (WF-VMAT)—for hippocampal and scalp sparing in whole-brain radiotherapy (WBRT), and to provide a basis for selecting the optimal clinical treatment plan.
Methods
Data from 22 patients receiving WBRT were retrospectively analyzed. Based on the RTOG 0933 protocol, PF-VMAT, NC-VMAT, and WF-VMAT plans were designed for each patient using the Eclipse treatment planning system. The three plan groups were compared regarding target coverage, dose homogeneity, conformity, and radiation dose to organs at risk (OARs) including the hippocampus, lenses, optic nerves, and scalp. Statistical analysis was performed.
Results
All plans met the RTOG 0933 dose constraints. For the PTV, PF-VMAT demonstrated significantly lower D 2% and D 50% compared to the other two techniques (p < 0.05). Regarding hippocampal sparing, both PF-VMAT and NC-VMAT achieved significantly lower D min and D mean to the hippocampus compared to WF-VMAT (p < 0.05). For other OARs, NC-VMAT significantly reduced the D max to the lenses, optic chiasm, and scalp (p < 0.05). PF-VMAT required significantly higher monitor units (MU) than the other two plans (p < 0.05).
Conclusion
NC-VMAT offers significant dosimetric advantages for scalp and visual structure sparing. It is particularly suitable for patients requiring high protection for these organs, albeit with increased treatment complexity and time due to its non-coplanar nature. PF-VMAT provides hippocampal sparing comparable to NC-VMAT and superior control of high-dose regions (lower D 2% ) but at the cost of higher MU. WF-VMAT is less effective in protecting OARs compared to NC-VMAT and PF-VMAT. Considering the balance between dosimetric gain and practical feasibility, PF-VMAT represents a pragmatic choice for routine clinical use, as it provides adequate target coverage and OAR sparing while eliminating the need for couch rotations during treatment.
Zitieren
APA
Zeng, H., Lin, Y., Chen, Z., Tang, S., Lin, Q., & Wen, Z. (2026). Evaluation of dosimetric parameters in three volumetric modulated arc therapy regimens for hippocampal and scalp sparing in whole-brain radiation therapy. Frontiers in Physics, 14. https://doi.org/10.3389/fphy.2026.1843325
Vancouver
Zeng H, Lin Y, Chen Z, Tang S, Lin Q, Wen Z. Evaluation of dosimetric parameters in three volumetric modulated arc therapy regimens for hippocampal and scalp sparing in whole-brain radiation therapy. Frontiers in Physics. 2026;14. doi:10.3389/fphy.2026.1843325
BibTeX
@article{Zeng2026,
author = {Zeng, Huaqu and Lin, Yangxing and Chen, Zongyou and Tang, Shukui and Lin, Qifu and Wen, Zunbei},
title = {Evaluation of dosimetric parameters in three volumetric modulated arc therapy regimens for hippocampal and scalp sparing in whole-brain radiation therapy},
journal = {Frontiers in Physics},
year = {2026},
volume = {14},
doi = {10.3389/fphy.2026.1843325}
}