EUVIMEDEUVIMED entdecken
Crossref

Evaluation of Pose Accuracy of the UR20 Industrial Robot

Iwona Pająk

Pomiary Automatyka Robotyka · 22.06.2026 · 30 (2) · 89-98

DOI: 10.14313/par_260/89 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pomiary Automatyka Robotyka, erschienen am 22.06.2026. Verfasst von Iwona Pająk.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents the results of experimental studies conducted to determine the pose accuracy of the UR20 robot from Universal Robots. The experiments followed the guidelines of the ISO 9283 standard, and the OptiTrack vision system was used to record the robot positions. The primary objective of the study was to determine position accuracy, while orientation accuracy was treated as an auxiliary result. Four alternative solutions to the inverse kinematics problem were tested, each enabling the robot mechanical interface to reach the same poses within the measurement cube defined according to ISO 9283. The mean position accuracies obtained for the tested configurations differed by approximately 1.5 mm, and the ratio of the maximum to the minimum value was about 2.6. The mean orientation errors were similar, with the ratio of the maximum to the minimum value being approximately 1.2. Statistical analysis confirmed that the robot initial configuration had a statistically significant effect on positioning accuracy. The obtained results indicate the need to consider alternative solutions of the inverse kinematics problem as a decision parameter in robot trajectory planning.

Zitieren

APA

Pająk, I. (2026). Evaluation of Pose Accuracy of the UR20 Industrial Robot. Pomiary Automatyka Robotyka, 30(2), 89-98. https://doi.org/10.14313/par_260/89

Vancouver

Pająk I. Evaluation of Pose Accuracy of the UR20 Industrial Robot. Pomiary Automatyka Robotyka. 2026;30(2):89-98. doi:10.14313/par_260/89

BibTeX
@article{Pajk2026,
  author = {Pająk, Iwona},
  title = {Evaluation of Pose Accuracy of the UR20 Industrial Robot},
  journal = {Pomiary Automatyka Robotyka},
  year = {2026},
  volume = {30},
  number = {2},
  pages = {89--98},
  doi = {10.14313/par_260/89}
}
Kostenlos starten →