A primary study of inverted right-angle configuration cannulated screws fixation of femoral neck fracture based on elaborated 3-dimensional features of the femoral head and neck region
PLOS One · 12.11.2026 · 21 (11) · e0361871
DOI: 10.1371/journal.pone.0361871 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, online erschienen am 12.11.2026. Verfasst von Changjian Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Traumatology and Orthopedics, The First Hospital of Dalian Medical University, Dalian, China. Hauptthemen laut MEDLINE: Bone Screws, Femoral Neck Fractures, Fracture Fixation, Internal, Femur Neck. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
CT-based three-dimensional (3D) reconstruction was used to analyze the detailed anatomical morphology of the femoral head-neck region, and a modified inverted right-angle cannulated screw configuration was proposed to reduce the risk of posterosuperior screw in-out-in (IOI) placement during femoral neck fracture fixation.
Methods
Imaging data from 22 patients (12 males and 10 females; mean age, 52.5 ± 16.8 years) were retrospectively analyzed. CT data of both hips were imported into Mimics to construct 3D digital femoral models for morphologic analysis and screw trajectory simulation. Based on the observed anterior offset of the femoral head-neck canal and the sloped posterosuperior cortex of the femoral neck, a modified inverted right-angle screw configuration and a negative anteversion fluoroscopic view were proposed. Technical feasibility was preliminarily illustrated in two patients with femoral neck fractures.
Results
The femoral head-neck axis showed an anterior offset relative to the proximal femoral axis, which may increase the risk of posterosuperior IOI screw trajectory with the traditional inverted triangle configuration. In the 3D simulation, the modified inverted right-angle configuration placed the posterosuperior screw within the proposed safety zone. The negative anteversion fluoroscopic view appeared useful for identifying potential IOI screw trajectory. Technical feasibility of the proposed configuration was illustrated in two patients with femoral neck fractures, in whom no postoperative IOI screw displacement was observed on CT.
Conclusion
The anatomical features of the femoral head-neck region may contribute to the risk of posterosuperior IOI screw trajectory with the traditional inverted triangle configuration. In this CT-based morphologic and simulation study, the modified inverted right-angle configuration showed a more favorable simulated position of the posterosuperior screw within the proposed safety zone, while negative anteversion fluoroscopy may help identify potential IOI screw trajectory. These preliminary findings require further validation through biomechanical studies and larger comparative clinical investigations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Traumatology and Orthopedics, The First Hospital of Dalian Medical University, Dalian, China.
ORCID-Profile: Changjian Liu
Zitieren
APA
Liu, C., Zhang, H., Liu, Y., Liu, P., & Hou, Y. (2026). A primary study of inverted right-angle configuration cannulated screws fixation of femoral neck fracture based on elaborated 3-dimensional features of the femoral head and neck region. PLOS One, 21(11), e0361871. https://doi.org/10.1371/journal.pone.0361871
Vancouver
Liu C, Zhang H, Liu Y, Liu P, Hou Y. A primary study of inverted right-angle configuration cannulated screws fixation of femoral neck fracture based on elaborated 3-dimensional features of the femoral head and neck region. PLOS One. 2026;21(11):e0361871. doi:10.1371/journal.pone.0361871
BibTeX
@article{Liu2026,
author = {Liu, Changjian and Zhang, Hanwen and Liu, Yazhou and Liu, Peihan and Hou, Yang},
title = {A primary study of inverted right-angle configuration cannulated screws fixation of femoral neck fracture based on elaborated 3-dimensional features of the femoral head and neck region},
journal = {PLOS One},
year = {2026},
volume = {21},
number = {11},
pages = {e0361871},
doi = {10.1371/journal.pone.0361871}
}
EUVIMED