Length-stable fixation reduces femoral neck shortening in unstable femoral neck fractures: A retrospective comparative study of length-stable dynamic hip screw versus femoral neck system fixation
Journal of Orthopaedic Surgery · 2026
DOI: 10.1177/10225536261415697 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Orthopaedic Surgery, 2026. Verfasst von Seonghyun Kang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Korea University Medicine, Korea University Guro Hospital, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Femoral Neck Fractures, Fracture Fixation, Internal, Bone Screws, Femur Neck. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Korea Health Industry Development Institute, AO Foundation.
Abstract (Originalsprache)
Background
Femoral neck shortening following internal fixation of unstable femoral neck fractures can compromise functional recovery, particularly in young, active patients. This study aimed to evaluate the efficacy of a length-stable dynamic hip screw (LSD) construct in minimizing postoperative shortening compared to the femoral neck system (FNS).
Methods
A retrospective review was conducted on 65 patients with high-grade unstable femoral neck fractures treated between February 2016 and February 2023 at a single institution. Patients underwent either FNS ( n = 31) or LSD ( n = 34) fixation. Femoral neck shortening was quantified using vector-based analysis derived from contralateral femoral comparison at final follow-up. Functional outcomes were assessed using the Hip Disability and Osteoarthritis Outcome Score (HOOS).
Results
The LSD group demonstrated significantly less femoral neck shortening compared to the FNS group (5.0 ± 4.6 mm vs 10.4 ± 6.7 mm, p = 0.001). Final HOOS scores were significantly higher in the LSD group in the symptom (88.1 vs 75.8, p = 0.049) and stiffness subdomains. Union was achieved in 31 of 34 patients (91.2%) in the LSD group and 26 of 31 (83.9%) in the FNS group ( p = 0.605). Other complications were more frequent in the FNS group but did not reach statistical significance.
Conclusion
Length-stable fixation using the LSD construct significantly reduced postoperative femoral neck shortening in high-grade unstable fractures, without compromising union rates or functional recovery. Our results support the role of length-stable constructs as a reliable option for maintaining anatomic integrity in unstable femoral neck fractures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Korea University Medicine, Korea University Guro Hospital, Seoul, Republic of Korea.
- Department of Orthopaedic Surgery, Chungbuk National University College of Medicine, Chungbuk National University Hospital, Cheongju, Republic of Korea.
- Department of Orthopaedic Surgery, University of California San Diego, San Diego, CA, USA.
- Department of Orthopaedic Surgery, Yeungnam University Medical Center, Daegu, Republic of Korea.
ORCID-Profile: Seonghyun Kang, Wonseok Choi, Eic Ju Lim, Jae-Woo Cho
Förderung
- Korea Health Industry Development Institute
- AO Foundation
Zitieren
APA
Kang, S., Choi, W., Choi, J. S., Lim, E. J., Ahn, S., Oh, J. K., Kent, W. T., Son, W. S., & Cho, J. W. (2026). Length-stable fixation reduces femoral neck shortening in unstable femoral neck fractures: A retrospective comparative study of length-stable dynamic hip screw versus femoral neck system fixation. Journal of Orthopaedic Surgery. https://doi.org/10.1177/10225536261415697
Vancouver
Kang S, Choi W, Choi JS, Lim EJ, Ahn S, Oh JK, et al. Length-stable fixation reduces femoral neck shortening in unstable femoral neck fractures: A retrospective comparative study of length-stable dynamic hip screw versus femoral neck system fixation. Journal of Orthopaedic Surgery. 2026. doi:10.1177/10225536261415697
BibTeX
@article{Kang2026,
author = {Kang, Seonghyun and Choi, Wonseok and Choi, Jeong Seok and Lim, Eic Ju and Ahn, SungJin and Oh, Jong-Keon and Kent, William T and Son, Whee Sung and Cho, Jae-Woo},
title = {Length-stable fixation reduces femoral neck shortening in unstable femoral neck fractures: A retrospective comparative study of length-stable dynamic hip screw versus femoral neck system fixation},
journal = {Journal of Orthopaedic Surgery},
year = {2026},
doi = {10.1177/10225536261415697}
}
EUVIMED