Salivary osmolality measured by MX3 hydration testing system demonstrates high reliability but limited validity in elite athlete hydration assessment

Stefan Pettersson iD, Lykke Tamm, Stig Mattsson iD, Anton Kalén

PLOS One · 2026

DOI: 10.1371/journal.pone.0349955 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, 2026. Verfasst von Stefan Pettersson und 3 weiteren Autor:innen. Beteiligte Einrichtung: Center for Health and Performance, Department of Food and Nutrition, and Sport Science, University of Gothenburg, Gothenburg, Sweden. Hauptthemen laut MEDLINE: Saliva, Athletes, Organism Hydration Status. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate assessment of hydration is essential for both athletic performance and health, yet remains challenging outside controlled settings. This study evaluated the validity and reliability of salivary osmolality (SOSM), measured using a handheld osmometer (MX3 Hydration Testing System), as a marker of morning hydration status in elite athletes. A total of 230 paired fasted-morning saliva and urine sample sets from 118 Olympic-level athletes (57% female; age 27 ± 5 years; BMI 24 ± 2) were included in the analyses. Urine specific gravity (USG) served as the reference. Validity was examined using ICC(3,1), ROC analysis, and Cohen’s κ, and test–retest reliability was assessed from three repeated SOSM readings from the same saliva sample. SOSM showed no meaningful correspondence with USG (ICC = 0.00; 95% CI [−0.13, 0.13]) and no meaningful classification agreement (κ = −0.02; 95% CI [−0.15, 0.10]). Diagnostic accuracy was poor across all examined threshold comparisons, with AUCs of 0.40–0.49, indicating chance-level to worse-than-chance discrimination, sensitivity 40–69%, and specificity 23–65%. By contrast, within-sample repeated SOSM measurements were highly consistent (ICC = 0.93; 95% CI [0.91, 0.94]), with a standard error of measurement of 7.9 mOsm and a minimal detectable change (MDC 90 ) of 18.4 mOsm. These findings indicate that the MX3 device is repeatable when reading the same saliva sample, but SOSM lacks validity as a stand-alone marker of first-morning hydration status in elite athletes under free-living conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SalivaAthletesOrganism Hydration StatusHumansFemaleOsmolar ConcentrationAdultReproducibility of ResultsMaleSpecific GravityYoung Adult

Autor:innen und Institutionen

  • Center for Health and Performance, Department of Food and Nutrition, and Sport Science, University of Gothenburg, Gothenburg, Sweden.
  • Swedish Olympic Committee, Sofiatornet, Olympiastadion, Stockholm, Sweden.
  • Department of Computer Science, Electrical and Space Engineering, Luleå University of Technology, Luleå, Sweden.

ORCID-Profile: Stefan Pettersson, Stig Mattsson

Zitieren

APA

Pettersson, S., Tamm, L., Mattsson, S., & Kalén, A. (2026). Salivary osmolality measured by MX3 hydration testing system demonstrates high reliability but limited validity in elite athlete hydration assessment. PLOS One. https://doi.org/10.1371/journal.pone.0349955

Vancouver

Pettersson S, Tamm L, Mattsson S, Kalén A. Salivary osmolality measured by MX3 hydration testing system demonstrates high reliability but limited validity in elite athlete hydration assessment. PLOS One. 2026. doi:10.1371/journal.pone.0349955

BibTeX
@article{Pettersson2026,
  author = {Pettersson, Stefan and Tamm, Lykke and Mattsson, Stig and Kalén, Anton},
  title = {Salivary osmolality measured by MX3 hydration testing system demonstrates high reliability but limited validity in elite athlete hydration assessment},
  journal = {PLOS One},
  year = {2026},
  doi = {10.1371/journal.pone.0349955}
}
Kostenlos starten →