ThermiQuant™ AquaStream: A portable instrument for quantitative colorimetric isothermal nucleic acid amplification reactions in paper and tube formats
PLOS One · 15.05.2026 · 21 (5) · e0348607
DOI: 10.1371/journal.pone.0348607 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, online erschienen am 15.05.2026. Verfasst von Bibek Raut und 6 weiteren Autor:innen. Beteiligte Einrichtung: Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, United States of America. Hauptthemen laut MEDLINE: Colorimetry, Nucleic Acid Amplification Techniques, Molecular Diagnostic Techniques, SARS-CoV-2. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Center for Produce Safety, Agricultural Marketing Service, Animal and Plant Health Inspection Service.
Abstract (Originalsprache)
Microfluidic paper-based analytical devices (µPADs) are an attractive format for colorimetric nucleic acid amplification tests (NAATs) because they enable low-cost, portable diagnostics in resource-limited settings. However, researchers often optimize colorimetric assays in liquid reactions in tubes before translating them to µPADs. Since both formats require separate instruments for incubation and real-time sensing, direct comparison of reactions between the two formats is difficult. To address these cross-platform limitations, we developed ThermiQuant™ AquaStream, a portable benchtop device (15 × 20 × 16 cm, ~ 5 kg; cost: USD 327) that supports seamless colorimetric loop-mediated isothermal amplification (LAMP) reactions in both µPADs and tubes under a common workflow. The system enables real-time reaction tracking (every 30 seconds) through onboard image processing, precise isothermal control (±0.5 °C) using a repurposed consumer-grade sous-vide heater, and medium-throughput (24 tubes or 42 µPADs). Testing with synthetic SARS-CoV-2 orf7ab DNA fragments demonstrated a limit of detection corresponding to a 95% probability of detection (LOD95) of 110 copies per reaction in tube (22 copies/µL) and 39 copies per reaction in µPADs (5 copies/µL), estimated using probit regression. In both formats the limit of quantification (LOQ), defined as the lowest concentration yielding a coefficient of variation (CV) of quantification time (Tq) ≤ 10%, was 250 copies/reaction resulting in a strong linear (R 2 = 0.98 & R 2 = 0.96 respectively for tube and µPADs) standard calibration curves. ThermiQuant™ AquaStream provides an affordable and versatile benchtop platform capable of supporting both tube- and µPAD-based colorimetric LAMP assays, serving as a proof-of-concept research tool for assay development and molecular diagnostics in One Health settings such as clinics, farms, and field environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, United States of America.
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, Indiana, United States of America.
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, United States of America.
- Purdue Institute of Inflammation, Immunology and Infectious Disease, Purdue University, West Lafayette, Indiana, United States of America.
- Purdue Institute for a Sustainable Future, Purdue University, West Lafayette, Indiana, United States of America.
- Bindley Bioscience Center, Purdue University, West Lafayette, Indiana, United States of America.
ORCID-Profile: Bibek Raut, Jiangshan Wang, Virendra Kumar, Mohit S Verma
Förderung
- Center for Produce Safety
- Agricultural Marketing Service
- Animal and Plant Health Inspection Service
Zitieren
APA
Raut, B., Palla, G., Wang, J., Campbell, S., Kumar, V., Ra, K., & Verma, M. S. (2026). ThermiQuant™ AquaStream: A portable instrument for quantitative colorimetric isothermal nucleic acid amplification reactions in paper and tube formats. PLOS One, 21(5), e0348607. https://doi.org/10.1371/journal.pone.0348607
Vancouver
Raut B, Palla G, Wang J, Campbell S, Kumar V, Ra K, et al. ThermiQuant™ AquaStream: A portable instrument for quantitative colorimetric isothermal nucleic acid amplification reactions in paper and tube formats. PLOS One. 2026;21(5):e0348607. doi:10.1371/journal.pone.0348607
BibTeX
@article{Raut2026,
author = {Raut, Bibek and Palla, Gopal and Wang, Jiangshan and Campbell, Skyler and Kumar, Virendra and Ra, Kyungyeon and Verma, Mohit S},
title = {ThermiQuant™ AquaStream: A portable instrument for quantitative colorimetric isothermal nucleic acid amplification reactions in paper and tube formats},
journal = {PLOS One},
year = {2026},
volume = {21},
number = {5},
pages = {e0348607},
doi = {10.1371/journal.pone.0348607}
}
EUVIMED