An exploratory dosimetric and treatment-time analysis of tangent-arc and continuous semi-arc VMAT in deep inspiration breath-hold radiotherapy for stage I left-sided breast cancer
PLOS One · 08.05.2026 · 21 (5) · e0348570
DOI: 10.1371/journal.pone.0348570 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, online erschienen am 08.05.2026. Verfasst von Yucheng Li und 9 weiteren Autor:innen. Beteiligte Einrichtung: Cancer Center, Department of Radiation Oncology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hang…. Hauptthemen laut MEDLINE: Breath Holding, Unilateral Breast Neoplasms, Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Zhejiang Province.
Abstract (Originalsprache)
Background
The use of the deep inspiration breath-hold (DIBH) technique reduces cardiac and lung radiation exposure during left breast cancer radiotherapy. However, the optimal beam delivery technique and the effects of patient adaptation during DIBH remain incompletely understood.
Objective
In this study, the dosimetric differences between continuous semi-arc and tangent-arc plans in stage I left-sided breast cancer patients using DIBH were compared, and the treatment session duration was descriptively analyzed to characterize treatment-time trends during routine DIBH delivery.
Methods
Twenty patients treated at our hospital from 01/05/2022–31/05/2023 were retrospectively selected from the institutional database for exploratory dosimetric analysis. Two radiotherapy plans were created on the basis of each patient’s computed tomography (CT) images. Dosimetric parameters for the planning target volume (PTV) and organs at risk (OARs), and beam-on and total treatment times, were compared.
Results
The conformity index (CI) for the PTV was significantly better with the continuous semi-arc plan ( P < 0.05), whereas the other PTV parameters did not significantly differ between the plans ( P > 0.05). The doses and beam-on time for all OARs (except the left ventricle) were significantly lower for the tangent-arc plan ( P < 0.05). Treatment time tended to stabilize across fractions, with a significant difference between the 15th and 16th sessions ( P < 0.05).
Conclusion
With the tangent-arc plan, the beam-on time and radiation exposure to OARs were observed to be lower, while adequate PTV coverage was maintained in patients with stage I left-sided breast cancer using DIBH. Treatment times tended to stabilize with increasing treatment fractions. This observation suggests gradual patient adaptation during routine DIBH rather than a predefined training effect. Given the exploratory nature of these findings and the limited sample size from a single institution, these findings should be interpreted with caution and warrant further investigation in larger, multicenter studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Cancer Center, Department of Radiation Oncology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China.
- School of Medical Technology, Yunnan Engineering Vocational College, Yunnan, China.
- Center for Rehabilitation Medicine, Rehabilitation & Sports Medicine Research Institute of Zhejiang Province, Department of Rehabilitation Medicine, Zhejiang Provincial People's Hospital (Affiliated People's Hospital),…
ORCID-Profile: Yucheng Li, Weijun Chen
Förderung
- Natural Science Foundation of Zhejiang Province
Zitieren
APA
Li, Y., Chen, Y., Xu, C., Zhan, W., Shao, K., Jia, Y., Zhang, H., Qiu, L., Ding, J., & Chen, W. (2026). An exploratory dosimetric and treatment-time analysis of tangent-arc and continuous semi-arc VMAT in deep inspiration breath-hold radiotherapy for stage I left-sided breast cancer. PLOS One, 21(5), e0348570. https://doi.org/10.1371/journal.pone.0348570
Vancouver
Li Y, Chen Y, Xu C, Zhan W, Shao K, Jia Y, et al. An exploratory dosimetric and treatment-time analysis of tangent-arc and continuous semi-arc VMAT in deep inspiration breath-hold radiotherapy for stage I left-sided breast cancer. PLOS One. 2026;21(5):e0348570. doi:10.1371/journal.pone.0348570
BibTeX
@article{Li2026,
author = {Li, Yucheng and Chen, Yinan and Xu, Chaoqing and Zhan, Wenming and Shao, Kainan and Jia, Yongshi and Zhang, Haibo and Qiu, Lingyun and Ding, Jieni and Chen, Weijun},
title = {An exploratory dosimetric and treatment-time analysis of tangent-arc and continuous semi-arc VMAT in deep inspiration breath-hold radiotherapy for stage I left-sided breast cancer},
journal = {PLOS One},
year = {2026},
volume = {21},
number = {5},
pages = {e0348570},
doi = {10.1371/journal.pone.0348570}
}
EUVIMED