EUVIMEDEUVIMED entdecken
Crossref

Rapid Selection of Patients Suitable for Deep Inspiration Breath-Hold Using an Automatic Delineating System and RapidPlan Model in Patients With Left Breast Cancer Undergoing Adjuvant Radiation Therapy With IMRT

Ying-Ying Zhou, Yan-Ning Li, Jin-Feng Xu, Bo Chen, Hua-Li Li, Yue-Xin Zheng, Li-Sheng Pan, Long-Mei Cai, Hong-Mei Wang

International Journal of Radiation Oncology*Biology*Physics · 2024

DOI: 10.1016/j.ijrobp.2024.06.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Radiation Oncology*Biology*Physics, 2024. Verfasst von Ying-Ying Zhou und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Nanfang Hospital, Southern Medical University, Guangzhou, China. Hauptthemen laut MEDLINE: Breath Holding, Radiotherapy Planning, Computer-Assisted, Heart, Unilateral Breast Neoplasms. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Nanfang Hospital, Southern Medical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study aimed to determine whether radiation therapy plans created using an automatic delineating system and a RapidPlan (RP) module could rapidly and accurately predict heart doses and benefit from deep inspiratory breath-hold (DIBH) in patients with left breast cancer. METHODS AND MATERIALS: One hundred thirty-six clinically approved free breathing (FB) plans for patients with left breast cancer were included, defined as manual delineation-manual plan (MD-MP). A total of 104 of 136 plans were selected for RP model training. A total of 32 of 136 patients were automatically delineated by software, after which the RP generated plans, defined as automatic delineation-RapidPlan (AD-RP). In addition, 40 patients who used DIBH were included to analyze differences in heart benefits from DIBH. RESULTS: Two RP models were established for post-breast-conserving surgery (BCS) and post-modified radical mastectomy. There were no significant differences in most of the dosimetric parameters between the MD-MP and AD-RP. The heart doses of the 2 plans were strongly correlated in patients after BCS (0.80 ≤ r ≤ 0.88, P < .05) and moderately correlated in patients after postmodified radical mastectomy (0.46 ≤ r ≤ 0.58, P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breath HoldingRadiotherapy Planning, Computer-AssistedHeartUnilateral Breast NeoplasmsRadiotherapy, Intensity-ModulatedOrgans at RiskMastectomy, SegmentalHumansFemaleRadiotherapy, AdjuvantMiddle AgedRadiotherapy DosagePatient SelectionAgedInhalationMastectomy, Modified RadicalAdultBreast Neoplasms

Autor:innen und Institutionen

  • Department of Radiation Oncology, Nanfang Hospital, Southern Medical University, Guangzhou, China.
  • School of Biomedical Engineering, Southern Medical University, Guangzhou, China.
  • The First School of Clinical Medicine, Southern Medical University, Guangzhou, China.
  • Department of Radiation Oncology, Nanfang Hospital, Southern Medical University, Guangzhou, China. Electronic address: clm520@i.smu.edu.cn.
  • Department of Radiation Oncology, Nanfang Hospital, Southern Medical University, Guangzhou, China. Electronic address: hongmeiw18@163.com.

Förderung

  • Nanfang Hospital
  • Southern Medical University

Zitieren

APA

Zhou, Y. Y., Li, Y. N., Xu, J. F., Chen, B., Li, H. L., Zheng, Y. X., Pan, L. S., Cai, L. M., & Wang, H. M. (2024). Rapid Selection of Patients Suitable for Deep Inspiration Breath-Hold Using an Automatic Delineating System and RapidPlan Model in Patients With Left Breast Cancer Undergoing Adjuvant Radiation Therapy With IMRT. International Journal of Radiation Oncology*Biology*Physics. https://doi.org/10.1016/j.ijrobp.2024.06.006

Vancouver

Zhou YY, Li YN, Xu JF, Chen B, Li HL, Zheng YX, et al. Rapid Selection of Patients Suitable for Deep Inspiration Breath-Hold Using an Automatic Delineating System and RapidPlan Model in Patients With Left Breast Cancer Undergoing Adjuvant Radiation Therapy With IMRT. International Journal of Radiation Oncology*Biology*Physics. 2024. doi:10.1016/j.ijrobp.2024.06.006

BibTeX
@article{Zhou2024,
  author = {Zhou, Ying-Ying and Li, Yan-Ning and Xu, Jin-Feng and Chen, Bo and Li, Hua-Li and Zheng, Yue-Xin and Pan, Li-Sheng and Cai, Long-Mei and Wang, Hong-Mei},
  title = {Rapid Selection of Patients Suitable for Deep Inspiration Breath-Hold Using an Automatic Delineating System and RapidPlan Model in Patients With Left Breast Cancer Undergoing Adjuvant Radiation Therapy With IMRT},
  journal = {International Journal of Radiation Oncology*Biology*Physics},
  year = {2024},
  doi = {10.1016/j.ijrobp.2024.06.006}
}