Algorithm-assisted interpretation of cyclic and differential pulse voltammetry for cardiac troponin detection
PLOS One · 13.05.2026 · 21 (5) · e0348348
DOI: 10.1371/journal.pone.0348348 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, online erschienen am 13.05.2026. Verfasst von Wikan Danar Sunindyo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Knowledge and Software Engineering Research Group, School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, West Java, …. Hauptthemen laut MEDLINE: Algorithms, Electrochemical Techniques, Troponin. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institut Teknologi Bandung.
Abstract (Originalsprache)
Cardiovascular disease remains a leading cause of mortality worldwide, and rapid identification of cardiac biomarkers is essential for early detection. Electrochemical voltammetry techniques, particularly cyclic voltammetry (CV) and differential pulse voltammetry (DPV), are widely used for detecting cardiac troponin; however, interpretation of raw voltammetric signals is often affected by baseline drift, signal noise, and operator-dependent analysis. This study proposes an algorithm-assisted analytical framework for automated interpretation of voltammetric data obtained from a screen-printed carbon electrode potentiostat. Polynomial fitting was applied for baseline correction in CV signals, while asymmetric least squares (ALS) was employed for DPV data. Peak-to-baseline current response was extracted as a quantitative indicator of biomarker presence. The proposed method successfully identified characteristic voltammetric peaks and distinguished samples with higher and lower cardiac biomarker responses relative to a predefined detection threshold. The analysis showed close agreement with reference electrochemical analysis software, demonstrating reliable peak detection and baseline estimation. By reducing manual interpretation and improving signal clarity, the framework enhances the reproducibility and accessibility of electrochemical biosensor measurements and supports early screening of cardiac biomarkers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Knowledge and Software Engineering Research Group, School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, West Java, Indonesia.
- Lab on Chip Laboratory, Biomedical Engineering Department, School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, West Java, Indonesia.
- School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, West Java, Indonesia.
- University Center of Excellence on Microelectronics, Institut Teknologi Bandung, Bandung, West Java, Indonesia.
- Graduate School of Natural Science and Technology, Kanazawa University, Kanazawa, Japan.
ORCID-Profile: Wikan Danar Sunindyo, Infall Syafalni
Förderung
- Institut Teknologi Bandung
Zitieren
APA
Sunindyo, W. D., Anshori, I., Wiguna, K. A., Kahari, M. M. H., Syafalni, I., Dwiyanti, L., & Uperianti (2026). Algorithm-assisted interpretation of cyclic and differential pulse voltammetry for cardiac troponin detection. PLOS One, 21(5), e0348348. https://doi.org/10.1371/journal.pone.0348348
Vancouver
Sunindyo WD, Anshori I, Wiguna KA, Kahari MMH, Syafalni I, Dwiyanti L, et al. Algorithm-assisted interpretation of cyclic and differential pulse voltammetry for cardiac troponin detection. PLOS One. 2026;21(5):e0348348. doi:10.1371/journal.pone.0348348
BibTeX
@article{Sunindyo2026,
author = {Sunindyo, Wikan Danar and Anshori, Isa and Wiguna, Kristo Abdi and Kahari, Marcelus Michael Herman and Syafalni, Infall and Dwiyanti, Latifa and Uperianti, Uperianti},
title = {Algorithm-assisted interpretation of cyclic and differential pulse voltammetry for cardiac troponin detection},
journal = {PLOS One},
year = {2026},
volume = {21},
number = {5},
pages = {e0348348},
doi = {10.1371/journal.pone.0348348}
}
EUVIMED