EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optical quality of Fresnel-structured hyperopic implantable collamer lenses: A ray-tracing analysis

Kimiya Shimizu iD, Takushi Kawamorita iD

PLOS One · 07.04.2026 · 21 (4) · e0345116

DOI: 10.1371/journal.pone.0345116 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, online erschienen am 07.04.2026. Verfasst von Kimiya Shimizu und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Eye Center, Sanno Hospital, Minato-ku, Tokyo, Japan. Hauptthemen laut MEDLINE: Hyperopia, Phakic Intraocular Lenses. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Kitasato University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To achieve positive refractive power, implantable collamer lenses (ICLs) for hyperopia increase central thickness, which in turn raises the risk of pupil blockage and lens contact in eyes with shallow anterior chambers. Additionally, incorporating a central hole raises concerns about stray light and halo formation due to increased thickness. This study used optical simulation to evaluate the imaging performance of hyperopic ICLs, highlighting the Fresnel structure’s potential to reduce thickness while maintaining imaging performance. Optical simulations were performed using Ansys Zemax OpticStudio 2024 R2 (Ansys, Inc.). An ICL with +10.00 D correction was designed for the Liou & Brennan model eye. The vault was set to 0.50 mm, and the central hole diameter was set to 0.36 mm. Fresnel ICLs (Fr. ICLs) with step heights ranging from 25 to 100 µm were compared with the reference ICL (Ref. ICL). Modulation transfer function (MTF) analyses were performed at internal artificial pupil diameters of 3.00 mm and 4.50 mm, both with and without holes. By reducing the central thickness from 0.80 mm to 0.40 mm, the Fr. ICL for hyperopia showed higher MTF values than the Ref. ICL at both pupil diameters. The difference was particularly significant at 4.50 mm. A slight MTF decrease due to the central hole was observed at 3.00 mm internal artificial pupil diameter. A step height of 50 µm or more suppressed contrast reduction at high spatial frequencies. Although further research is needed in illumination optics and clinical studies, ray-tracing simulations have demonstrated that the designed hyperopia-correcting Fr. ICL can reduce central thickness while maintaining or improving optical performance, making it a promising candidate for clinical application.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HyperopiaPhakic Intraocular LensesHumansComputer SimulationRefraction, Ocular

Autor:innen und Institutionen

  • Department of Eye Center, Sanno Hospital, Minato-ku, Tokyo, Japan.
  • International University of Health and Welfare, Minato-ku, Tokyo, Japan.
  • Department of Orthoptics and Visual Science, Kitasato University, Sagamihara, Kanagawa, Japan.

ORCID-Profile: Kimiya Shimizu, Takushi Kawamorita

Förderung

  • Kitasato University

Zitieren

APA

Shimizu, K., & Kawamorita, T. (2026). Optical quality of Fresnel-structured hyperopic implantable collamer lenses: A ray-tracing analysis. PLOS One, 21(4), e0345116. https://doi.org/10.1371/journal.pone.0345116

Vancouver

Shimizu K, Kawamorita T. Optical quality of Fresnel-structured hyperopic implantable collamer lenses: A ray-tracing analysis. PLOS One. 2026;21(4):e0345116. doi:10.1371/journal.pone.0345116

BibTeX
@article{Shimizu2026,
  author = {Shimizu, Kimiya and Kawamorita, Takushi},
  title = {Optical quality of Fresnel-structured hyperopic implantable collamer lenses: A ray-tracing analysis},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {4},
  pages = {e0345116},
  doi = {10.1371/journal.pone.0345116}
}
Kostenlos starten →