Comparison of higher-order aberrations between implantable collamer lens V4c implantation and simulated spectacle correction in patients with high myopia
Journal Français d'Ophtalmologie · 2023-06 · 46 (6) · 630-638
DOI: 10.1016/j.jfo.2022.11.024 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal Français d'Ophtalmologie, 2023-06. Verfasst von J Zhu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China; Clinical Research…. Hauptthemen laut MEDLINE: Astigmatism, Phakic Intraocular Lenses, Myopia. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Major Scientific and Technological Project of Zhejiang Province, Chinese Academy of Sciences, Zhejiang Province Natural Science Foundation.
Abstract (Originalsprache)
PURPOSE: To investigate the differences in higher-order aberrations between non-toric or toric implantable collamer lens (ICL or TICL) V4c implantation and simulated spectacle correction. METHODS: Patients with high myopia who underwent ICL/TICL V4c implantation were enrolled. The "total no defocus" pattern of iTrace aberrometry to simulate the condition of spectacle correction was measured before ICL/TICL implantation, and higher-order aberrations in this condition were compared to those 3 months after surgery. Related factors with changes in coma were comprehensively analyzed. RESULTS: A total of 89 right eyes of 89 patients were included. Compared to simulated spectacle correction, total-eye coma (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China; Clinical Research Center, First Affiliated Hospital, College of Medicine, Zhejiang Univ…
Förderung
- Major Scientific and Technological Project of Zhejiang Province
- Chinese Academy of Sciences
- Zhejiang Province Natural Science Foundation
Zitieren
APA
Zhu, J., Guo, D., Jin, L., Zhou, T., Shan, S., Zhu, H., Zhang, L., Tong, J., & Shen, Y. (2023). Comparison of higher-order aberrations between implantable collamer lens V4c implantation and simulated spectacle correction in patients with high myopia. Journal Français d'Ophtalmologie, 46(6), 630-638. https://doi.org/10.1016/j.jfo.2022.11.024
Vancouver
Zhu J, Guo D, Jin L, Zhou T, Shan S, Zhu H, et al. Comparison of higher-order aberrations between implantable collamer lens V4c implantation and simulated spectacle correction in patients with high myopia. Journal Français d'Ophtalmologie. 2023;46(6):630-638. doi:10.1016/j.jfo.2022.11.024
BibTeX
@article{Zhu2023,
author = {Zhu, J and Guo, D and Jin, L and Zhou, T and Shan, S and Zhu, H and Zhang, L and Tong, J and Shen, Y},
title = {Comparison of higher-order aberrations between implantable collamer lens V4c implantation and simulated spectacle correction in patients with high myopia},
journal = {Journal Français d'Ophtalmologie},
year = {2023},
volume = {46},
number = {6},
pages = {630--638},
doi = {10.1016/j.jfo.2022.11.024}
}
EUVIMED