EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ventricular activation and repolarization in response to physiological and conventional pacing using ultra-high-frequency electrocardiography

Saúl Palacios iD, Radovan Smisek, Karol Curila, Uyen Nguyen iD, Frits W Prinzen, Josef Halamek, Filip Plesinger, Pavel Jurak, Javier Ramos, Juan Pablo Martínez iD, Esther Pueyo iD

PLOS One · 13.04.2026 · 21 (4) · e0344111

DOI: 10.1371/journal.pone.0344111 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, online erschienen am 13.04.2026. Verfasst von Saúl Palacios und 10 weiteren Autor:innen. Beteiligte Einrichtung: BSICoS Group, Aragon Institute of Engineering Research, IIS Aragon, University of Zaragoza, Zaragoza, Spain. Hauptthemen laut MEDLINE: Electrocardiography, Cardiac Pacing, Artificial, Heart Ventricles, Bradycardia. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 81 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Agencia Estatal de Investigación, Gobierno de Aragón.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Physiological pacing targeting the cardiac conduction system is increasingly being adopted as an alternative to conventional right ventricular (RV) pacing for the treatment of bradyarrhythmias, although its effects on ventricular repolarization remain underexplored.

Objective

This study evaluates depolarization and repolarization responses to different pacing techniques using ultra-high-frequency electrocardiograms (UHF-ECGs).

Methods

Temporary pacing was performed at different cardiac areas in 178 patients with bradycardia. Depolarization was assessed via QRS duration (QRS d ), QRS area (QRS a ), ventricular dyssynchrony (e-DYS), and activation time dispersion (dAT computed from leads V1-V6 and dAT 4-6 from leads V1-V6). Repolarization was analyzed using the corrected QT interval (QTc), T-wave area (T a ), Periodic Repolarization Dynamics (PRD), and repolarization time dispersion (dRTc and dRTc 4-6 ).

Results

His bundle pacing (HBP) preserved ventricular activation patterns similar to spontaneous rhythm. Left bundle branch pacing (LBBP) induced moderate depolarization changes, primarily due to delayed right ventricular activation, while maintaining left ventricular synchrony. In particular, dAT showed no significant differences between HBP and spontaneous rhythm, while differences between LBBAP and spontaneous rhythm were significant but below 7 ms in median. When restricted to the left ventricle (LV), no significant differences in dAT 4-6 were found between LBBAP and spontaneous rhythm. Importantly, e-DYS for HBP showed similar values to spontaneous rhythm, LBBP led to a significant reduction (median differences approximately 20 ms), and RVP was associated with a significant increase (above 15 ms in median). In line with these results, QRS d and QRS a showed the largest values for RVP. In terms of ventricular repolarization, median differences in the QTc interval between pacing modes and spontaneous rhythm were below 3 ms for HBP, above 1 ms for LBBP, and above 20 ms for RVP. All pacing modes led to a reduction in PRD, with the most marked reductions observed for LBBP, particularly for selective LBBP, with median changes with respect to spontaneous rhythm of 4.6 degrees. RT and RTc showed similar trends for all pacing techniques. T a , however, showed median differences with respect to spontaneous rhythm above 100 and 34 μ Vs when pacing the RV at the apex and the septum, respectively, whereas such median differences were below 16 μ Vs for HBP and below 2 μ Vs for LBBP.

Conclusion

Physiological stimulation via HBP or LBBAP generates ventricular depolarization and repolarization responses that more closely resembles that of spontaneous rhythm, in high contrast to the largely different response induced by RV pacing. HBP and LBBAP have distinct technical characteristics, including differences in capture thresholds, lead stability, and procedural aspects. These techniques serve as alternatives to conventional RV pacing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocardiographyCardiac Pacing, ArtificialHeart VentriclesBradycardiaHumansFemaleMaleBundle of HisHeart Conduction System

Autor:innen und Institutionen

  • BSICoS Group, Aragon Institute of Engineering Research, IIS Aragon, University of Zaragoza, Zaragoza, Spain.
  • Institute of Scientific Instruments, the Czech Academy of Sciences, Brno, Czech Republic.
  • Charles University and University Hospital Kralovske Vinohrad, Cardiocenter, 3rd Faculty of Medicine, Prague, Czech Republic.
  • Maastricht University Medical Centre (MUMC), Maastricht, The Netherlands.
  • Arrhythmias Unit, Department of Cardiology, Hospital Clinico Lozano Blesa, Zaragoza, Spain.
  • CIBER en Bioingeniería, Biomateriales y Nanomedicina, Zaragoza, Spain.

ORCID-Profile: Saúl Palacios, Uyen Nguyen, Juan Pablo Martínez, Esther Pueyo

Förderung

  • Agencia Estatal de Investigación
  • Gobierno de Aragón

Zitieren

APA

Palacios, S., Smisek, R., Curila, K., Nguyen, U., Prinzen, F. W., Halamek, J., Plesinger, F., Jurak, P., Ramos, J., Martínez, J. P., & Pueyo, E. (2026). Ventricular activation and repolarization in response to physiological and conventional pacing using ultra-high-frequency electrocardiography. PLOS One, 21(4), e0344111. https://doi.org/10.1371/journal.pone.0344111

Vancouver

Palacios S, Smisek R, Curila K, Nguyen U, Prinzen FW, Halamek J, et al. Ventricular activation and repolarization in response to physiological and conventional pacing using ultra-high-frequency electrocardiography. PLOS One. 2026;21(4):e0344111. doi:10.1371/journal.pone.0344111

BibTeX
@article{Palacios2026,
  author = {Palacios, Saúl and Smisek, Radovan and Curila, Karol and Nguyen, Uyen and Prinzen, Frits W and Halamek, Josef and Plesinger, Filip and Jurak, Pavel and Ramos, Javier and Martínez, Juan Pablo and Pueyo, Esther},
  title = {Ventricular activation and repolarization in response to physiological and conventional pacing using ultra-high-frequency electrocardiography},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {4},
  pages = {e0344111},
  doi = {10.1371/journal.pone.0344111}
}
Kostenlos starten →