EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improving the measurement resolution in BOTDR sensor with optimized wavelet denoising strategy

Mustafa Essa Hamzah, Mohd Saiful Dzulkefly Zan iD, Abdulwahhab Essa Hamzah, Mohd Faisal Ibrahim, Ahmad Ashrif A Bakar, Hisham Mohamad, Yosuke Tanaka

PLOS One · 21.01.2026 · 21 (1) · e0341131

DOI: 10.1371/journal.pone.0341131 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, online erschienen am 21.01.2026. Verfasst von Mustafa Essa Hamzah und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia (UKM), Ban…. Hauptthemen laut MEDLINE: Wavelet Analysis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universiti Kebangsaan Malaysia, Ministry of Higher Education, Malaysia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Signal averaging imposes a significant trade-off between measurement time and measurand resolution in a sub-meter differential cross-spectrum Brillouin optical time domain reflectometry (DCS-BOTDR). This article introduces an optimized post-processing strategy that integrates wavelet denoising (WD) function with a traditional Lorentzian curve fitting (LCF) under relatively low signal averages to mitigate this problem. Symlet, Daubechies, Coiflet, and Biorthogonal Spline WD functions with a 4-level decomposition were executed on a six-core CPU utilizing a single-program-multiple-data (SPMD) paradigm and compared. Experimental validation was executed over distances of 350 meters and 1.21 kilometers of single-mode fiber. The experimental results demonstrate a 2.7 times reduction in required signal averages, in which the proposed LCF + WD method achieved a 2.7 MHz Brillouin frequency shift (BFS) resolution with only 21000 averages, a performance that required 56000 averages using the LCF method alone. To manage the computational load on the large experimental datasets, the algorithm was implemented on a parallel six-core architecture, accelerating the data processing speed by up to 4.8 times compared to serial computation. The method also successfully preserved a 0.4 m spatial resolution and improved temperature resolution to 3°C across a 1.21 km fiber at just 14000 signal averages. In comparison to other methods such as machine learning-based enhancements, the proposed strategy presents a more straightforward, training-free execution that attains comparable BFS and temperature resolutions without the necessity of extensive datasets or rigorous model training. Together with the multicore architecture, the proposed strategy is particularly beneficial for real-time distributed sensing applications where computational resources may be constrained.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wavelet AnalysisAlgorithmsSignal Processing, Computer-Assisted

Autor:innen und Institutionen

  • Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi, Selangor, Malaysia.
  • Department of Communications Engineering, Iraq University College, Basrah, Iraq.
  • Civil & Environmental Engineering Department, Universiti Teknologi PETRONAS, Seri Iskandar, Perak, Malaysia.
  • Division of Advanced Electrical and Electronic Engineering, Institute of Engineering, Tokyo University of Agriculture and Technology, Naka-cho, Koganei, Tokyo, Japan.

ORCID-Profile: Mohd Saiful Dzulkefly Zan

Förderung

  • Universiti Kebangsaan Malaysia
  • Ministry of Higher Education, Malaysia

Zitieren

APA

Hamzah, M. E., Zan, M. S. D., Hamzah, A. E., Ibrahim, M. F., A Bakar, A. A., Mohamad, H., & Tanaka, Y. (2026). Improving the measurement resolution in BOTDR sensor with optimized wavelet denoising strategy. PLOS One, 21(1), e0341131. https://doi.org/10.1371/journal.pone.0341131

Vancouver

Hamzah ME, Zan MSD, Hamzah AE, Ibrahim MF, A Bakar AA, Mohamad H, et al. Improving the measurement resolution in BOTDR sensor with optimized wavelet denoising strategy. PLOS One. 2026;21(1):e0341131. doi:10.1371/journal.pone.0341131

BibTeX
@article{Hamzah2026,
  author = {Hamzah, Mustafa Essa and Zan, Mohd Saiful Dzulkefly and Hamzah, Abdulwahhab Essa and Ibrahim, Mohd Faisal and A Bakar, Ahmad Ashrif and Mohamad, Hisham and Tanaka, Yosuke},
  title = {Improving the measurement resolution in BOTDR sensor with optimized wavelet denoising strategy},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {1},
  pages = {e0341131},
  doi = {10.1371/journal.pone.0341131}
}
Kostenlos starten →