Fachartikel in der Zeitschrift PLOS One, online erschienen am 04.11.2025. Verfasst von Dibyajyoti Mohanta und 5 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Environmental and Climate Science, Lund University, Lund, Sweden. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Barncancerfonden, VetenskapsrÃ¥det.
Abstract (Originalsprache)
Fluorescence microscopy is an effective tool for imaging biological samples, yet captured images often contain noises, including photon shot noise and camera read noise. To analyze biological samples accurately, separating background pixels from signal pixels is crucial. This would ideally be guided by the knowledge of a parameter called the Poisson parameter, λ bg , representing the mean number of photons collected in a background pixel (for the case when quantum efficiency = 1 and the dark current is negligible). This study introduces a method for estimating λ bg , from an image which contains both background and signal pixels, using probabilistic noise modeling for an sCMOS camera. The approach incorporates Poisson-distributed photon shot noise and sCMOS camera read noise modelled with a Tukey-Lambda distribution. We apply a chi-square test and a truncated fit technique to estimate λ bg directly from a general sCMOS image, with camera parameters determined through calibration experiments. We validate our method by comparing λ bg estimates in images captured by sCMOS and EMCCD cameras for the same field of view. Our analysis shows strong agreement for low to moderate exposure images, where estimated values for λ bg align well between the sCMOS and EMCCD images. Based on our estimated λ bg , we perform image thresholding and segmentation using our previously introduced procedure. Our publicly available software provides a platform for photophysical image analysis for sCMOS camera systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Centre for Environmental and Climate Science, Lund University, Lund, Sweden.
- Department of Chemistry, The State University of New York at Buffalo, New York, United States of America.
- Department of Life Sciences, Chalmers University of Technology, Gothenburg, Sweden.
ORCID-Profile: Dibyajyoti Mohanta, Albertas Dvirnas
Förderung
- Barncancerfonden
- Vetenskapsrådet
Zitieren
APA
Mohanta, D., Kunnath, R. N., Clarkson, E., Dvirnas, A., Westerlund, F., & Ambjörnsson, T. (2025). Photophysical image analysis for sCMOS cameras: Noise modelling and estimation of background parameters in fluorescence-microscopy images. PLOS One, 20(11), e0335310. https://doi.org/10.1371/journal.pone.0335310
Vancouver
Mohanta D, Kunnath RN, Clarkson E, Dvirnas A, Westerlund F, Ambjörnsson T. Photophysical image analysis for sCMOS cameras: Noise modelling and estimation of background parameters in fluorescence-microscopy images. PLOS One. 2025;20(11):e0335310. doi:10.1371/journal.pone.0335310
BibTeX
@article{Mohanta2025,
author = {Mohanta, Dibyajyoti and Kunnath, Radhika Nambannor and Clarkson, Erik and Dvirnas, Albertas and Westerlund, Fredrik and Ambjörnsson, Tobias},
title = {Photophysical image analysis for sCMOS cameras: Noise modelling and estimation of background parameters in fluorescence-microscopy images},
journal = {PLOS One},
year = {2025},
volume = {20},
number = {11},
pages = {e0335310},
doi = {10.1371/journal.pone.0335310}
}
EUVIMED