EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Dosimetric comparison of Monte Carlo, Acuros XB, and anisotropic analytical algorithm for lung cancer plans on halcyon accelerators

Kainan Shao iD, Chaojun Chai iD, Yiwei Yang, Weijun Chen iD, Fenglei Du iD

PLOS One · 2025

DOI: 10.1371/journal.pone.0334329 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift PLOS One, 2025. Verfasst von Kainan Shao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Cancer Center, Department of Radiation Oncology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hang…. Hauptthemen laut MEDLINE: Monte Carlo Method, Lung Neoplasms, Algorithms, Radiotherapy Planning, Computer-Assisted. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Basic Public Welfare Research Program of Zhejiang Province, Medical Science and Technology Project of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluates the differences in application of the RayStation Monte Carlo algorithm (RMC) compared to Acuros XB (AXB) and the Anisotropic Analytical Algorithm (AAA) in Eclipse for conventional radiotherapy planning of lung cancer using the novel ring-shaped Halcyon accelerator. A total of 63 non-small-cell lung cancer patients were retrospectively included, with a prescription dose of 60 Gy delivered in 30 fractions. Radiotherapy plans were initially designed and optimized in RayStation, then recalculated in Eclipse using AXB and AAA to assess algorithmic differences in dose distributions. Analysis of data from 63 patients, combined with simulations using square fields and cylindrical water phantoms, revealed that RMC and AXB achieved high consistency in target dose coverage and conformity. High-dose indicators, such as D 2% and D 0.03cc , showed close agreement between RMC and AAA, while AXB tended to slightly underestimate peak doses. For prescription dose coverage metrics like D 95% and D 98% , the difference between RMC and AXB was less than 1%, whereas AAA exhibited minor degradation. In organ-at-risk dose evaluations, RMC delivered higher doses compared to AXB and AAA, with AAA doses exceeding those of AXB. These findings confirm the dose consistency of RayStation and Eclipse algorithms for use with the Halcyon accelerator. The RayStation Monte Carlo algorithm (RMC) is a viable alternative to AXB, especially in lung cancer cases with high tissue heterogeneity, as target coverage and conformity discrepancies remain within 0.5%. Additionally, recalculation of RMC-optimized plans in Eclipse using AXB resulted in lower organ-at-risk doses. Therefore, recalculations performed before treatment do not compromise the clinical adequacy of volumetric dose evaluations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Monte Carlo MethodLung NeoplasmsAlgorithmsRadiotherapy Planning, Computer-AssistedCarcinoma, Non-Small-Cell LungParticle AcceleratorsRadiometryHumansRadiotherapy DosageRetrospective StudiesAnisotropyPhantoms, Imaging

Autor:innen und Institutionen

  • Cancer Center, Department of Radiation Oncology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China.
  • Department of Radiation Physics, Zhejiang Cancer Hospital, Hangzhou Institute of Medicine (HIM), Chinese Academy of Sciences, Hangzhou, Zhejiang, China.

ORCID-Profile: Kainan Shao, Chaojun Chai, Weijun Chen, Fenglei Du

Förderung

  • Basic Public Welfare Research Program of Zhejiang Province
  • Medical Science and Technology Project of Zhejiang Province

Zitieren

APA

Shao, K., Chai, C., Yang, Y., Chen, W., & Du, F. (2025). Dosimetric comparison of Monte Carlo, Acuros XB, and anisotropic analytical algorithm for lung cancer plans on halcyon accelerators. PLOS One. https://doi.org/10.1371/journal.pone.0334329

Vancouver

Shao K, Chai C, Yang Y, Chen W, Du F. Dosimetric comparison of Monte Carlo, Acuros XB, and anisotropic analytical algorithm for lung cancer plans on halcyon accelerators. PLOS One. 2025. doi:10.1371/journal.pone.0334329

BibTeX
@article{Shao2025,
  author = {Shao, Kainan and Chai, Chaojun and Yang, Yiwei and Chen, Weijun and Du, Fenglei},
  title = {Dosimetric comparison of Monte Carlo, Acuros XB, and anisotropic analytical algorithm for lung cancer plans on halcyon accelerators},
  journal = {PLOS One},
  year = {2025},
  doi = {10.1371/journal.pone.0334329}
}
Kostenlos starten →