EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC0

Enhancing reproducibility in stable isotope analysis (SIA) of fish eye lenses: A comparison between lamina number and diameter

Alexandra Chu iD, Danhong Ally Li iD, Miranda Bell-Tilcock, Miranda Lowe-Webb, Carson Jeffres, Rachel C Johnson

PLOS One · 26.06.2025 · 20 (6) · e0326345

DOI: 10.1371/journal.pone.0326345 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift PLOS One, online erschienen am 26.06.2025. Verfasst von Alexandra Chu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center for Watershed Sciences, University of California, Davis, California, United States of America. Hauptthemen laut MEDLINE: Lens, Crystalline, Salmon. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC0). Gefördert von: California Department of Fish and Wildlife.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Analyzing stable isotopes in archival tissues, such as fish eye lenses, is used to document shifts in feeding ecology, diet, habitat use, and to reconstruct life history. Fish eye lenses grow throughout their ontogeny, forming multiple sequential layers, or laminae. These laminae represent the chronology of the fish’s life, much like tree rings, which record environmental conditions over time. Lenses are protein-rich, which makes them an ideal structure for analyzing light isotopes such as δ¹³C, δ¹⁵N, and δ 34 S. These light isotopes are primarily integrated into the lens tissue through the fish’s diet, where they are bound to amino acid structures during protein synthesis. As research begins to emerge using eye lenses to reconstruct the life histories of fishes, the need for a reproducible method of delamination grows. For this study, each researcher independently delaminated one lens from each of the 10 adult Chinook Salmon ( Oncorhynchus tshawytscha ). Lens lamina number, diameter (mm), and mass (mg) of each lamina were recorded. Laminae were then submitted for stable isotope analysis of both δ¹³C and δ¹⁵N. Isotope values were used as a validation to compare delamination patterns between researchers. δ¹³C and δ¹⁵N values from the lenses were then plotted using both the assigned lamina number and lens diameter to compare the difference between researchers. Analysis based on lamina number showed significant shifts in isotope values and variability in lamina counts between researchers. However, when lens diameter was used instead of lamina number, isotope patterns throughout the lenses of the same fish were nearly identical. Using lens diameter removes subjectivity between researchers, thereby increasing the reproducibility of the technique and providing a more robust interpretation of the data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lens, CrystallineSalmonAnimalsReproducibility of ResultsNitrogen IsotopesCarbon Isotopes

Substanzen

Nitrogen IsotopesCarbon Isotopes

Autor:innen und Institutionen

  • Center for Watershed Sciences, University of California, Davis, California, United States of America.
  • Delta Stewardship Council, Sacramento, California, United States of America.
  • National Marine Fisheries Service, Southwest Fisheries Science Center, Santa Cruz, California, United States of America.

ORCID-Profile: Alexandra Chu, Danhong Ally Li

Förderung

  • California Department of Fish and Wildlife

Zitieren

APA

Chu, A., Li, D. A., Bell-Tilcock, M., Lowe-Webb, M., Jeffres, C., & Johnson, R. C. (2025). Enhancing reproducibility in stable isotope analysis (SIA) of fish eye lenses: A comparison between lamina number and diameter. PLOS One, 20(6), e0326345. https://doi.org/10.1371/journal.pone.0326345

Vancouver

Chu A, Li DA, Bell-Tilcock M, Lowe-Webb M, Jeffres C, Johnson RC. Enhancing reproducibility in stable isotope analysis (SIA) of fish eye lenses: A comparison between lamina number and diameter. PLOS One. 2025;20(6):e0326345. doi:10.1371/journal.pone.0326345

BibTeX
@article{Chu2025,
  author = {Chu, Alexandra and Li, Danhong Ally and Bell-Tilcock, Miranda and Lowe-Webb, Miranda and Jeffres, Carson and Johnson, Rachel C},
  title = {Enhancing reproducibility in stable isotope analysis (SIA) of fish eye lenses: A comparison between lamina number and diameter},
  journal = {PLOS One},
  year = {2025},
  volume = {20},
  number = {6},
  pages = {e0326345},
  doi = {10.1371/journal.pone.0326345}
}
Kostenlos starten →