EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Application of a porous graphitic carbon column to carbon and nitrogen isotope analysis of underivatized individual amino acids using high‐performance liquid chromatography coupled with elemental analyzer/isotope ratio mass spectrometry

Yuchen Sun iD, Nanako O Ogawa, Naoto F Ishikawa, Thomas M Blattmann, Yoshinori Takano, Naohiko Ohkouchi

Rapid Communications in Mass Spectrometry · 2023

DOI: 10.1002/rcm.9602 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2023. Verfasst von Yuchen Sun und 5 weiteren Autor:innen. Beteiligte Einrichtung: Biogeochemistry Research Center (BGC), Japan Agency for Marine-Earth Science and Technology (JAMSTEC), Yokosuka, Japan. Hauptthemen laut MEDLINE: Amino Acids, Graphite. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

Isolation of underivatized amino acids (AAs) using high‐performance liquid chromatography (HPLC) is becoming a popular method for carbon (δ 13 C) and nitrogen isotope (δ 15 N) analyses of AAs because of the high analytical precision and for performing dual‐isotope analysis. However, some AAs in natural samples, especially small, hydrophilic AAs, are not suitably separated using reversed‐phase columns (e.g., C18) and ion‐exchange columns (e.g., Primesep A).

Methods

We developed a new method for HPLC using a porous graphitic carbon column for the separation of nine hydrophilic AAs. After purification, δ 13 C and δ 15 N values of AAs were determined using elemental analyzer/isotope ratio mass spectrometry (EA/IRMS). We demonstrated the application of this method by determining δ 13 C and δ 15 N values of individual hydrophilic AAs in a biological sample, the muscle of blue mackerel ( Scomber australasicus ).

Results

Chromatographically, the baseline separation of hydrophilic AAs was achieved in both the standard mixture and the biological sample. We confirmed that δ 13 C and δ 15 N values of AA standards remained unchanged during the whole experimental procedure. The δ 13 C values of AAs in mackerel muscle are also in good agreement with the values obtained using another verified method for δ 13 C analysis.

Conclusions

The good separation performance of hydrophilic AAs and the reliability of δ 13 C and δ 15 N analyses of individual AAs using the porous graphite column offer a significant advantage over conventional settings. We suggest that, in the future, the HPLC × EA/IRMS method can be used for reliable δ 13 C and δ 15 N analyses of AAs in natural samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Amino AcidsGraphiteChromatography, High Pressure LiquidCarbonNitrogen IsotopesPorosityReproducibility of ResultsCarbon IsotopesMass Spectrometry

Substanzen

Amino AcidsCarbonNitrogen IsotopesGraphiteCarbon Isotopes

Autor:innen und Institutionen

  • Biogeochemistry Research Center (BGC), Japan Agency for Marine-Earth Science and Technology (JAMSTEC), Yokosuka, Japan.
  • Atmosphere and Ocean Research Institute (AORI), The University of Tokyo, Kashiwa, Japan.
  • Department of Earth and Planetary Science, The University of Tokyo, Tokyo, Japan.
  • Geological Institute, ETH Zürich, Zürich, Switzerland.

ORCID-Profile: Yuchen Sun

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Sun, Y., Ogawa, N. O., Ishikawa, N. F., Blattmann, T. M., Takano, Y., & Ohkouchi, N. (2023). Application of a porous graphitic carbon column to carbon and nitrogen isotope analysis of underivatized individual amino acids using high‐performance liquid chromatography coupled with elemental analyzer/isotope ratio mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.9602

Vancouver

Sun Y, Ogawa NO, Ishikawa NF, Blattmann TM, Takano Y, Ohkouchi N. Application of a porous graphitic carbon column to carbon and nitrogen isotope analysis of underivatized individual amino acids using high‐performance liquid chromatography coupled with elemental analyzer/isotope ratio mass spectrometry. Rapid Communications in Mass Spectrometry. 2023. doi:10.1002/rcm.9602

BibTeX
@article{Sun2023,
  author = {Sun, Yuchen and Ogawa, Nanako O and Ishikawa, Naoto F and Blattmann, Thomas M and Takano, Yoshinori and Ohkouchi, Naohiko},
  title = {Application of a porous graphitic carbon column to carbon and nitrogen isotope analysis of underivatized individual amino acids using high‐performance liquid chromatography coupled with elemental analyzer/isotope ratio mass spectrometry},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2023},
  doi = {10.1002/rcm.9602}
}
Kostenlos starten →