Morphologic changes of the no-touch saphenous vein as Y-composite versus aortocoronary grafts (CONFIG Trial)
PLOS One · 2025
DOI: 10.1371/journal.pone.0322176 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift PLOS One, 2025. Verfasst von Suk Ho Sohn und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic…. Hauptthemen laut MEDLINE: Saphenous Vein, Coronary Artery Bypass, Aorta. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
This randomized controlled trial was aimed to compare 1-year morphologic changes of the no-touch saphenous vein graft as Y-composite (Composite group) versus aortocoronary (Aorta group) configurations in coronary artery bypass grafting.
Methods
The primary endpoint was intima-media thickness of the saphenous vein graft as measured by intravascular ultrasound (IVUS) at the 1-year angiographic evaluation. Recruitment of 25 patients in each group was necessary based on a superiority design. Among the 50 patients, IVUS data were obtained in 22 and 24 patients from the Composite and Aorta groups, respectively.
Results
Mean age was 64.8 ± 9.2 years, and the proportion of females was 20.0%. The numbers of distal anastomoses per saphenous vein graft were 2.7 ± 1.1 and 2.6 ± 0.8 in the Composite and Aorta groups, respectively. The intima-media thickness of the saphenous vein graft 1 year after surgery were 0.25 ± 0.04 mm and 0.24 ± 0.06 mm in the Composite and Aorta groups, respectively ( P for superiority = .99). Other IVUS parameters of saphenous vein grafts, including vessel diameter, luminal diameter, and the ratio of intima-media thickness to vessel diameter, also demonstrated no differences between the groups. No neointimal hyperplasia or plaque formation was detected using IVUS. All study patients underwent 1-year angiographic evaluation, and the patency rates were 94.7%(89 out of 94 anastomoses) and 100.0%(90 out of 90 anastomoses) in the Composite and Aorta groups, respectively.
Conclusions
The intima-media thickness of the saphenous vein graft 1 year after surgery demonstrated no significant difference between the Y-composite and aortocoronary configurations (NCT04782492). Trial Registration: ClinicalTrials.gov NCT04782492 .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea.
- Department of Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea.
ORCID-Profile: Suk Ho Sohn, Ji Seong Kim, Ho Young Hwang
Zitieren
APA
Sohn, S. H., Kang, Y., Kim, J. S., Kang, J., & Hwang, H. Y. (2025). Morphologic changes of the no-touch saphenous vein as Y-composite versus aortocoronary grafts (CONFIG Trial). PLOS One. https://doi.org/10.1371/journal.pone.0322176
Vancouver
Sohn SH, Kang Y, Kim JS, Kang J, Hwang HY. Morphologic changes of the no-touch saphenous vein as Y-composite versus aortocoronary grafts (CONFIG Trial). PLOS One. 2025. doi:10.1371/journal.pone.0322176
BibTeX
@article{Sohn2025,
author = {Sohn, Suk Ho and Kang, Yoonjin and Kim, Ji Seong and Kang, Jeehoon and Hwang, Ho Young},
title = {Morphologic changes of the no-touch saphenous vein as Y-composite versus aortocoronary grafts (CONFIG Trial)},
journal = {PLOS One},
year = {2025},
doi = {10.1371/journal.pone.0322176}
}
EUVIMED