EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simulated low-dose dark-field radiography for detection of COVID-19 pneumonia

Rafael C Schick iD, Henriette Bast, Manuela Frank iD, Theresa Urban iD, Thomas Koehler iD, Florian T Gassert iD, Andreas P Sauter, Bernhard Renger, Alexander A Fingerle iD, Alexandra Karrer, Marcus R Makowski, Daniela Pfeiffer und 1 weitere

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0316104 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Rafael C Schick und 12 weiteren Autor:innen. Beteiligte Einrichtung: Chair of Biomedical Physics, Department of Physics & School of Natural Sciences, Technical University of Munich, Garching bei München, Germany. Hauptthemen laut MEDLINE: COVID-19, Radiation Dosage, SARS-CoV-2. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Dark-field radiography has been proven to be a promising tool for the assessment of various lung diseases.

Purpose

To evaluate the potential of dose reduction in dark-field chest radiography for the detection of the Coronavirus SARS-CoV-2 (COVID-19) pneumonia. Materials and methods Patients aged at least 18 years with a medically indicated chest computed tomography scan (CT scan) were screened for participation in a prospective study between October 2018 and December 2020. Patients were included if they had a CO-RADS (COVID-19 Reporting and Data System) score ≥ 4 (COVID-19 group) or if they had no pathologic lung changes (controls). A total of 89 participants with a median age of 60 years (interquartile range 48 to 68 yrs.) were included in this study. Dark-field and attenuation-based radiographs were simultaneously obtained by using a prototype system for dark-field radiography. By modifying the image reconstruction algorithm, low-dose radiographs were simulated based on real participant images. The simulated radiographs corresponded to 50%, 25%, and 13% of the full dose (41.9 μSv, median value). Four experienced radiologists served as blinded readers assessing both image modalities, displayed side by side in random order. The presence of COVID-19-associated lung changes was rated on a scale from 1 to 6. The readers’ diagnostic performance was evaluated by analyzing the area under the receiver operating characteristic curves (AUC) using Obuchowski’s method. Also, the dark-field images were analyzed quantitatively by comparing the dark-field coefficients within and between the COVID-19 and the control group.

Results

The readers’ diagnostic performance in the image evaluation, as described by the AUC value (where a value of 1 corresponds to perfect diagnostic accuracy), did not differ significantly between the full dose images (AUC = 0.86) and the simulated images at 50% (AUC = 0.86) and 25% of the full dose(AUC = 0.84) (p>0.050), but was slightly lower at 13% dose (AUC = 0.82) (p = 0.038). For all four radiation dose levels, the median dark-field coefficients within groups were identical but different significantly by 15% between the controls and the COVID-19 pneumonia group (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

COVID-19Radiation DosageSARS-CoV-2HumansMiddle AgedMaleFemaleAgedProspective StudiesTomography, X-Ray ComputedLungPandemicsRadiography, ThoracicROC Curve

Autor:innen und Institutionen

  • Chair of Biomedical Physics, Department of Physics & School of Natural Sciences, Technical University of Munich, Garching bei München, Germany.
  • Munich Institute of Biomedical Engineering, Technical University of Munich, Garching bei München, Germany.
  • Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, München, Germany.
  • Philips Research, Hamburg, Germany.
  • Munich Institute for Advanced Study, Technical University of Munich, Garching bei München, Germany.
  • Kantonsspital Münsterlingen, Münsterlingen, Switzerland.

ORCID-Profile: Rafael C Schick, Manuela Frank, Theresa Urban, Thomas Koehler, Florian T Gassert, Alexander A Fingerle

Zitieren

APA

Schick, R. C., Bast, H., Frank, M., Urban, T., Koehler, T., Gassert, F. T., Sauter, A. P., Renger, B., Fingerle, A. A., Karrer, A., Makowski, M. R., Pfeiffer, D., & Pfeiffer, F. (2024). Simulated low-dose dark-field radiography for detection of COVID-19 pneumonia. PLOS ONE. https://doi.org/10.1371/journal.pone.0316104

Vancouver

Schick RC, Bast H, Frank M, Urban T, Koehler T, Gassert FT, et al. Simulated low-dose dark-field radiography for detection of COVID-19 pneumonia. PLOS ONE. 2024. doi:10.1371/journal.pone.0316104

BibTeX
@article{Schick2024,
  author = {Schick, Rafael C and Bast, Henriette and Frank, Manuela and Urban, Theresa and Koehler, Thomas and Gassert, Florian T and Sauter, Andreas P and Renger, Bernhard and Fingerle, Alexander A and Karrer, Alexandra and Makowski, Marcus R and Pfeiffer, Daniela and Pfeiffer, Franz},
  title = {Simulated low-dose dark-field radiography for detection of COVID-19 pneumonia},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0316104}
}