Evaluation of the performance of a qPCR-based assay for HIV-1 viral load determination
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0315579 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift PLOS ONE, 2024. Verfasst von Bin Lin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of HIV/AIDS Control and Prevention, Shandong Center for Disease Control and Prevention, Jinan, Shandong Province, China. Hauptthemen laut MEDLINE: HIV-1, Viral Load, HIV Infections, Real-Time Polymerase Chain Reaction. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Shandong Province, Medical and Health Technology Project of Shandong Province.
Abstract (Originalsprache)
Objective
According to the YY/T 1182–2010 standard of the People’s Republic of China on nucleic acid amplification test reagents (kits) for medical industry, the accuracy, precision, linear range, and analytic sensitivity of HIV-1 standardized quality control products should be assessed. The Geneway HIV-1 Nucleic Acid Detection Kit from China has been successfully registered with the National Medical Products Administration. Here, we aimed to assess for the first time its detection performance.
Methods
The accuracy, precision, analytic sensitivity, and linearity of the Geneway HIV-1 nucleic acid quantification test kit were analyzed using a series of diluted standard control samples of HIV-1 negative plasma. Clinical plasma samples were collected from 163 HIV-infected patients and 38 HIV-negative patients. The detection performance of the Geneway assay was compared with that of the US FDA-approved COBAS AmpliPrep/COBAS® Taqman® HIV-1 test (Roche), version 2.0, for viral load (VL) monitoring.
Results
The absolute deviation of the assay between the logarithm of the measured concentration and the logarithm of the expected concentration did not exceed ±0.5 logarithmic units. All coefficients of variation (CV%) for the assays were within 5%, indicating good precision in the detection. The linearity of quantitation was excellent (r = 0.999). Overall agreement was observed in 198 of the 201 specimens (98.51%), with a kappa value of 0.953. Bland-Altman analysis revealed an average difference of 0.030 between the two assays, with 95.95% (142/148) of the differences falling within the 95% confidence limits of agreement (−0.50, 0.56). Linear regression results demonstrated a strong linear correlation between the two assays, with a high Pearson correlation coefficient (r = 0.980) and coefficient of determination (R 2 = 0.960, p < 0.001).
Conclusions
The Geneway HIV-1 VL assay demonstrated excellent accuracy, precision, analytic sensitivity, and linearity. Compared to the Roche assay, the Geneway assay showed good performance for HIV-1 VL detection, supporting its use in clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Division of HIV/AIDS Control and Prevention, Shandong Center for Disease Control and Prevention, Jinan, Shandong Province, China.
- Clinical Laboratory, Zibo Center for Disease Control and Prevention, Zibo, Shandong Province, China.
- Department of Anesthesiology, Qilu Hospital of Shandong University, Jinan, Shandong Province, China.
ORCID-Profile: Bin Lin
Förderung
- Natural Science Foundation of Shandong Province
- Medical and Health Technology Project of Shandong Province
Zitieren
APA
Lin, B., Han, C., Li, J. H., & Wang, R. (2024). Evaluation of the performance of a qPCR-based assay for HIV-1 viral load determination. PLOS ONE. https://doi.org/10.1371/journal.pone.0315579
Vancouver
Lin B, Han C, Li JH, Wang R. Evaluation of the performance of a qPCR-based assay for HIV-1 viral load determination. PLOS ONE. 2024. doi:10.1371/journal.pone.0315579
BibTeX
@article{Lin2024,
author = {Lin, Bin and Han, Chao and Li, Jin-Hai and Wang, Rui},
title = {Evaluation of the performance of a qPCR-based assay for HIV-1 viral load determination},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0315579}
}
EUVIMED