Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Shuo Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, China. Hauptthemen laut MEDLINE: Models, Theoretical. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The energy information of pulse signals is significantly important for applications such as computed tomography (CT), positron emission tomography (PET), and research on defects in condensed matter. Time-over-threshold (TOT) and multi-voltage threshold (MVT) are commonly used digitization methods in sampling pulse signal. However, both approaches rely on a mathematical model of the pulse signal to derive energy information. This study proposes a semi-empirical mathematical model for pulse signals formation process in scintillation crystal-coupled photomultiplier tube(PMT) probes, by utilizing the CR-RC shaping method. This mathematical model accurately describes output of the PMT pulse signals. This study analyzes a substantial dataset of pulse signals, comparing the performance of the newly designed mathematical model with that of the double exponential function in terms of their ability to fit pulse signals. The results indicate that the mathematical model developed herein achieves an average R 2 of 0.9255, significantly surpassing the 0.9155 of the double exponential function, thereby demonstrating its superior fitting efficacy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Models, TheoreticalSignal Processing, Computer-AssistedScintillation CountingAlgorithms

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, China.
  • Raycan Technology Co., Ltd., Suzhou, Jiangsu, China.
  • Key Laboratory of Thermo-Fluid Science and Engineering, Ministry of Education, Xi'an Jiaotong University, Xi'an, China.

ORCID-Profile: Shuo Li

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Li, S., Lyu, X., Wang, F., & Sun, C. (2024). An accurate semi-empirical model for PMT pulse signal analysis. PLOS ONE. https://doi.org/10.1371/journal.pone.0313999

Vancouver

Li S, Lyu X, Wang F, Sun C. An accurate semi-empirical model for PMT pulse signal analysis. PLOS ONE. 2024. doi:10.1371/journal.pone.0313999

BibTeX
@article{Li2024,
  author = {Li, Shuo and Lyu, Xudong and Wang, Fei and Sun, Chao},
  title = {An accurate semi-empirical model for PMT pulse signal analysis},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0313999}
}
Kostenlos starten →