Enhancing time-resolution for radon measurements using airflow-through scintillation cells based on a compartmental model approach

Chao Zhao iD, Gang Han, Chongqing Hu, Yanliang Chen, Jiayu Liu, Fangdong Tang, Linfeng He

Radiation Protection Dosimetry · 2024

DOI: 10.1093/rpd/ncae062 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Chao Zhao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai Institute of Measurement and Testing Technology, 1500 Zhang-Heng Road, Shanghai 201203, China. Hauptthemen laut MEDLINE: Radon, Scintillation Counting, Air Pollutants, Radioactive, Radiation Monitoring. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 8 Literaturangaben. Gefördert von: National Natural Science Foundation of China, State Administration for Market Regulation Innovation Talent Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To overcome the time-resolution limitation inherent in the airflow-through scintillation cell method for radon measurement, this study introduces a compartmental model elucidating the behaviors of radon and its progeny within such cells. The computed results of the normalized equilibrium functions derived from the compartmental model, provide quantitative insights into the equilibrium progression of 222Rn and its progeny over time, substantiating the identified time-resolution limitation of 2–3 hours. Laboratory experiments confirm the efficacy of the proposed correction algorithm, showcasing its ability to surmount the time-resolution limitation and achieve a rapid response in radon measurement using airflow-through scintillation cells.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadonScintillation CountingAir Pollutants, RadioactiveRadiation MonitoringAlgorithmsRadon DaughtersTime FactorsHumansAir Pollution, IndoorModels, Theoretical

Substanzen

RadonAir Pollutants, RadioactiveRadon Daughters

Autor:innen und Institutionen

  • Shanghai Institute of Measurement and Testing Technology, 1500 Zhang-Heng Road, Shanghai 201203, China.

ORCID-Profile: Chao Zhao

Förderung

  • National Natural Science Foundation of China
  • State Administration for Market Regulation Innovation Talent Program

Zitieren

APA

Zhao, C., Han, G., Hu, C., Chen, Y., Liu, J., Tang, F., & He, L. (2024). Enhancing time-resolution for radon measurements using airflow-through scintillation cells based on a compartmental model approach. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae062

Vancouver

Zhao C, Han G, Hu C, Chen Y, Liu J, Tang F, et al. Enhancing time-resolution for radon measurements using airflow-through scintillation cells based on a compartmental model approach. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae062

BibTeX
@article{Zhao2024,
  author = {Zhao, Chao and Han, Gang and Hu, Chongqing and Chen, Yanliang and Liu, Jiayu and Tang, Fangdong and He, Linfeng},
  title = {Enhancing time-resolution for radon measurements using airflow-through scintillation cells based on a compartmental model approach},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  doi = {10.1093/rpd/ncae062}
}
Kostenlos starten →