Design and development of a sensorized hammerstone for accurate force measurement in stone knapping experiments
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0310520 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Cecilia Barroso-Medina und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Earth, Atmospheric and Life Sciences, University of Wollongong, Wollongong, NSW, Australia. Hauptthemen laut MEDLINE: Hominidae, Tool Use Behavior. Die Arbeit nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Research Council, University of Wollongong.
Abstract (Originalsprache)
The process of making stone tools, specifically knapping, is a hominin behaviour that typically involves using the upper limb to manipulate a stone hammer and apply concentrated percussive force to another stone, causing fracture and detachment of stone chips with sharp edges. To understand the emergence and subsequent evolution of tool-related behaviours in hominins, the connections between the mechanics of stone knapping, including the delivery of percussive forces, and biomechanics and hominin anatomy, especially in the upper limb, are required. However, there is an absence of direct experimental means to measure the actual forces generated and applied to produce flakes during knapping. Our study introduces a novel solution to this problem in the form of an ergonomic hand-held synthetic hammerstone that can record the percussive forces that occur during knapping experiments. This hammerstone is composed of a deformable pneumatic 3D-printed chamber encased within a 3D-printed grip and a stone-milled striker. During knapping, hammer impact causes the pneumatic chamber to deform, which leads to a change in pressure that is measured by a sensor. Comparisons of recorded pressure data against corresponding force values measured using a force plate show that the synthetic hammer quantifies percussion forces with relatively high accuracy. The performance of this hammerstone was further validated by conducting anvil-supported knapping experiments on glass that resulted in a root mean square error of under 6%, while recording forces up to 730 N with successful flake detachments. These validation results indicate that accuracy was not sensitive to variations up to 15° from the vertical in the hammer striking angle. Our approach allows future studies to directly examine the role of percussive force during the stone knapping process and its relationship with both anatomical and technological changes during human evolution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- School of Earth, Atmospheric and Life Sciences, University of Wollongong, Wollongong, NSW, Australia.
- Australian Research Council Centre of Excellence for Australian Biodiversity and Heritage, University of Wollongong, Wollongong, NSW, Australia.
- Department of Anthropology, Lakehead University, Thunder Bay, Ontario, Canada.
- Human Origins Program, National Museum of Natural History, Smithsonian Institution, Washington, D.C., United States of America.
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW, Australia.
ORCID-Profile: Cecilia Barroso-Medina, Sam C Lin, Manish Sreenivasa
Förderung
- Australian Research Council
- University of Wollongong
Zitieren
APA
Barroso-Medina, C., Lin, S. C., Tocheri, M. W., & Sreenivasa, M. (2024). Design and development of a sensorized hammerstone for accurate force measurement in stone knapping experiments. PLOS ONE. https://doi.org/10.1371/journal.pone.0310520
Vancouver
Barroso-Medina C, Lin SC, Tocheri MW, Sreenivasa M. Design and development of a sensorized hammerstone for accurate force measurement in stone knapping experiments. PLOS ONE. 2024. doi:10.1371/journal.pone.0310520
BibTeX
@article{BarrosoMedina2024,
author = {Barroso-Medina, Cecilia and Lin, Sam C and Tocheri, Matthew W and Sreenivasa, Manish},
title = {Design and development of a sensorized hammerstone for accurate force measurement in stone knapping experiments},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0310520}
}
EUVIMED