EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A semi-empirical relation based on temperature difference and filling ratio in a closed loop pulsating heat pipe: A numerical study

Vasanth Balamurugan, Shahid Mian P, Md Jahid Hasan iD, Natteri M Sudharsan iD

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0309108 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Vasanth Balamurugan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Rajalakshmi Engineering College, Chennai, Tamil Nadu, India. Hauptthemen laut MEDLINE: Hot Temperature. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A closed-loop pulsating heat pipe (CLPHP) is an attractive passive cooling system for electronic components. The design of CLPHP is challenging due to the complex nature of thermo-hydrodynamic coupling. This study investigates the heat transfer efficiency of a CLPHP using water as the working fluid. The heat transfer rate is evaluated for a volume fraction of 0.3-0.7 and an evaporator temperature of 323-373 K. From the computed results, a regression analysis is performed to generate a semi-empirical equation. The empirical relation for heat transfer rate (Q) as a function of the temperature difference and filling ratio was found to match the CFD results. Similarly, a semi-empirical equation for heat flux (q) as a function of non-dimensionless numbers is presented to calculate the heat transfer rate (Q) for various filling ratios, and found to match CFD results. A force plot measuring the net force acting on the slugs is presented for various filling ratios and evaporator temperatures. The net force plot will help optimize the design of the CLPHP and improve its efficiency. When comparing slug formation pulsatile cycle and thermal efficiency, 0.5 volume fraction was found to be optimum. For this filling ratio (0.5) heat transfer rate is enhanced from 40% to 86% when the evaporator temperature is increased by 15%.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hot TemperatureModels, TheoreticalHydrodynamicsTemperature

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Rajalakshmi Engineering College, Chennai, Tamil Nadu, India.
  • Department of Mechanical and Production Engineering (MPE), Islamic University of Technology (IUT), Board Bazar, Gazipur, Bangladesh.

ORCID-Profile: Md Jahid Hasan, Natteri M Sudharsan

Zitieren

APA

Balamurugan, V., Mian P, S., Hasan, M. J., & Sudharsan, N. M. (2024). A semi-empirical relation based on temperature difference and filling ratio in a closed loop pulsating heat pipe: A numerical study. PLOS ONE. https://doi.org/10.1371/journal.pone.0309108

Vancouver

Balamurugan V, Mian P S, Hasan MJ, Sudharsan NM. A semi-empirical relation based on temperature difference and filling ratio in a closed loop pulsating heat pipe: A numerical study. PLOS ONE. 2024. doi:10.1371/journal.pone.0309108

BibTeX
@article{Balamurugan2024,
  author = {Balamurugan, Vasanth and Mian P, Shahid and Hasan, Md Jahid and Sudharsan, Natteri M},
  title = {A semi-empirical relation based on temperature difference and filling ratio in a closed loop pulsating heat pipe: A numerical study},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0309108}
}
Kostenlos starten →