In Situ Biofilm Monitoring Using a Heat Transfer Sensor: The Impact of Flow Velocity in a Pipe and Planar System
Biosensors · 2025
DOI: 10.3390/bios15020093 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Andreas Netsch und 3 weiteren Autor:innen. Beteiligte Einrichtung: DVGW Research Center at the Engler-Bunte-Institut, Engler-Bunte-Ring 9a, 76131 Karlsruhe, Germany. Hauptthemen laut MEDLINE: Biofilms, Biosensing Techniques. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry of Education and Research, German Federal Ministry of Education and Research (BMBF), KIT-Publication Fund of the Karlsruhe Institute of Technology.
Abstract (Originalsprache)
Industrially applied bioelectrochemical systems require long-term stable operation, and hence the control of biofilm accumulation on the electrodes. An optimized application of biofilm control mechanisms presupposes on-line, in-situ monitoring of the accumulated biofilm. Heat transfer sensors have successfully been integrated into industrial systems for on-line, non-invasive monitoring of biofilms. In this study, a mathematical model for the description of the sensitivity of a heat transfer biofilm sensor was developed, incorporating the hydrodynamic conditions of the fluid and the geometrical properties of the substratum. This model was experimentally validated at different flow velocities by integrating biofilm sensors into cylindrical pipes and planar mesofluidic flow cells with a carbonaceous substratum. Dimensionless sensor readings were correlated with the mean biovolume measured gravimetrically, and optical coherence tomography was used to determine the sensors’ sensitivity. The biofilm sensors applied in the planar flow cells revealed an increase in sensitivity by a factor of 6 compared to standard stainless steel pipes, as well as improved sensitivity at higher flow velocities.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- DVGW Research Center at the Engler-Bunte-Institut, Engler-Bunte-Ring 9a, 76131 Karlsruhe, Germany.
- Engler-Bunte-Institut, Water Chemistry and Water Technology, Karlsruhe Institute of Technology (KIT), Engler-Bunte-Ring 9a, 76131 Karlsruhe, Germany.
- Institute for Biological Interfaces 1 (IBG-1), Institute for Biological Interfaces, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany.
ORCID-Profile: Andreas Netsch, Harald Horn, Michael Wagner
Förderung
- Federal Ministry of Education and Research
- German Federal Ministry of Education and Research (BMBF)
- KIT-Publication Fund of the Karlsruhe Institute of Technology
Zitieren
APA
Netsch, A., Sen, S., Horn, H., & Wagner, M. (2025). In Situ Biofilm Monitoring Using a Heat Transfer Sensor: The Impact of Flow Velocity in a Pipe and Planar System. Biosensors. https://doi.org/10.3390/bios15020093
Vancouver
Netsch A, Sen S, Horn H, Wagner M. In Situ Biofilm Monitoring Using a Heat Transfer Sensor: The Impact of Flow Velocity in a Pipe and Planar System. Biosensors. 2025. doi:10.3390/bios15020093
BibTeX
@article{Netsch2025,
author = {Netsch, Andreas and Sen, Shaswata and Horn, Harald and Wagner, Michael},
title = {In Situ Biofilm Monitoring Using a Heat Transfer Sensor: The Impact of Flow Velocity in a Pipe and Planar System},
journal = {Biosensors},
year = {2025},
doi = {10.3390/bios15020093}
}
EUVIMED