Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Zhaoxin Peng und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Hunan University of Science and Technology, Xiangtan, China. Hauptthemen laut MEDLINE: Optic Flow. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, Major Landmark Innovation Demonstration Project in Hunan Province, National Natural Science Foundation of Hunan Province.
Abstract (Originalsprache)
Complex steerable pyramid (CSP) performs well when applied to magnify subtle motions of structures for observing the dynamic characteristics of facilities. However, the impact of the types and parameters of CSP filters upon the performance of phase-based optical flow (PBOF) in measuring motion parameters has not been systematically studied. The purpose of this study is to comprehensively evaluate the impact of different CSP filter types (Octave, HalfOctave, SmoothHalfOctave, and QuarterOctave) and parameters on the performance of PBOF in measuring motion parameters. Firstly, by measuring simulated translational motion, the influence of the CSP’s down-sampling rates on the displacement measurement accuracy of PBOF is analyzed to determine appropriate settings. Subsequently, the effective displacement measurement interval and accuracy of PBOF using the CSP are studied through simulated and experimental translational motion measurements. Further, the vibration parameter’s accuracy is analyzed through simulated periodic vibration measurements. Finally, the characteristics of PBOF using the four kinds of CSP and practical considerations are discussed. Simulation and experimental results demonstrate that when using middle-level filters within the effective level range of HalfOctave, PBOF achieves the best overall displacement measurement performance. Additionally, this method can easily integrate with signal processing techniques in analyzing structural dynamic characteristics under field conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- School of Mechanical Engineering, Hunan University of Science and Technology, Xiangtan, China.
- Engineering Research Centre of Hunan Province for the Mining and Utilization of Wind Turbines Operation Data, Hunan University of Science and Technology, Xiangtan, China.
ORCID-Profile: Xian Wang
Förderung
- National Key Research and Development Program of China
- Major Landmark Innovation Demonstration Project in Hunan Province
- National Natural Science Foundation of Hunan Province
- Open Research Project of the National Key Laboratory of Offshore Wind Power Generation Equipment and Efficient Wind Energy Utilization
- Visiting Scholar Program of China Scholarship Council
Zitieren
APA
Peng, Z., Wang, X., Wang, Z., Liu, W., & Liu, M. (2024). Evaluation of the impact of filter types and parameters upon the accuracy of phase-based optical flow method with a complex steerable pyramid. PLOS ONE. https://doi.org/10.1371/journal.pone.0308943
Vancouver
Peng Z, Wang X, Wang Z, Liu W, Liu M. Evaluation of the impact of filter types and parameters upon the accuracy of phase-based optical flow method with a complex steerable pyramid. PLOS ONE. 2024. doi:10.1371/journal.pone.0308943
BibTeX
@article{Peng2024,
author = {Peng, Zhaoxin and Wang, Xian and Wang, Zhiliang and Liu, Wei and Liu, Menglian},
title = {Evaluation of the impact of filter types and parameters upon the accuracy of phase-based optical flow method with a complex steerable pyramid},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0308943}
}
EUVIMED