EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessment of material identification and quantification in the presence of metals using spectral photon counting CT

Briya Tariq iD, Osama Sikander, Nadine Francis, Manar Alkhatib, Farhat Naseer, Naoufel Werghi, Esat Memisoglu, Nabil Maalej, Aamir Raja

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0308658 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Briya Tariq und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, Khalifa University, Abu Dhabi, United Arab Emirates. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Phantoms, Imaging, Photons, Metals. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Khalifa University of Science, Technology and Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Spectral Photon Counting Computed Tomography (SPCCT), a ground-breaking development in CT technology, has immense potential to address the persistent problem of metal artefacts in CT images. This study aims to evaluate the potential of Mars photon-counting CT technology in reducing metal artefacts. It focuses on identifying and quantifying clinically significant materials in the presence of metal objects. A multi-material phantom was used, containing inserts of varying concentrations of hydroxyapatite (a mineral present in teeth, bones, and calcified plaque), iodine (used as a contrast agent), CT water (to mimic soft tissue), and adipose (as a fat substitute). Three sets of scans were acquired: with aluminium, with stainless steel, and without a metal insert as a reference dataset. Data acquisition was performed using a Mars SPCCT scanner (Microlab 5×120); operated at 118 kVp and 80 μA. The images were subsequently reconstructed into five energy bins: 7-40, 40-50, 50-60, 60-79, and 79-118 keV. Evaluation metrics including signal-to-noise ratio (SNR), linearity of attenuation profiles, root mean square error (RMSE), and area under the curve (AUC) were employed to assess the energy and material-density images with and without metal inserts. Results show decreased metal artefacts and a better signal-to-noise ratio (up to 25%) with increased energy bins as compared to reference data. The attenuation profile also demonstrated high linearity (R 2 >0.95) and lower RMSE across all material concentrations, even in the presence of aluminium and steel. Material identification accuracy for iodine and hydroxyapatite (with and without metal inserts) remained consistent, minimally impacting AUC values. For demonstration purposes, the biological sample was also scanned with the stainless steel volar implant and cortical bone screw, and the images were objectively assessed to indicate the potential effectiveness of SPCCT in replicating real-world clinical scenarios.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedPhantoms, ImagingPhotonsMetalsHumansSignal-To-Noise RatioArtifactsIodineDurapatite

Substanzen

MetalsIodineDurapatite

Autor:innen und Institutionen

  • Department of Physics, Khalifa University, Abu Dhabi, United Arab Emirates.
  • Department of Biomedical Engineering & Sciences, National University of Sciences and Technology, Islamabad, Pakistan.
  • Department of Robotics and Intelligent Machine Engineering, National University of Sciences and Technology, Islamabad, Pakistan.
  • Department of Electrical & Computer Engineering, Khalifa University, Abu Dhabi, United Arab Emirates.
  • Imaging Institute, Cleveland Clinic Abu Dhabi, Abu Dhabi, United Arab Emirates.

ORCID-Profile: Briya Tariq

Förderung

  • Khalifa University of Science, Technology and Research

Zitieren

APA

Tariq, B., Sikander, O., Francis, N., Alkhatib, M., Naseer, F., Werghi, N., Memisoglu, E., Maalej, N., & Raja, A. (2024). Assessment of material identification and quantification in the presence of metals using spectral photon counting CT. PLOS ONE. https://doi.org/10.1371/journal.pone.0308658

Vancouver

Tariq B, Sikander O, Francis N, Alkhatib M, Naseer F, Werghi N, et al. Assessment of material identification and quantification in the presence of metals using spectral photon counting CT. PLOS ONE. 2024. doi:10.1371/journal.pone.0308658

BibTeX
@article{Tariq2024,
  author = {Tariq, Briya and Sikander, Osama and Francis, Nadine and Alkhatib, Manar and Naseer, Farhat and Werghi, Naoufel and Memisoglu, Esat and Maalej, Nabil and Raja, Aamir},
  title = {Assessment of material identification and quantification in the presence of metals using spectral photon counting CT},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0308658}
}
Kostenlos starten →