The intra-day and inter-day reliability of a 6-second Wingate to determine maximal peak power in endurance-trained athletes
PLOS ONE · 06.09.2024 · 19 (9) · e0307325
DOI: 10.1371/journal.pone.0307325 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 06.09.2024. Verfasst von Joao Henrique Falk Neto und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Kinesiology, Sport and Recreation, University of Alberta, Edmonton, Alberta, Canada. Hauptthemen laut MEDLINE: Athletes, Physical Endurance, Exercise Test. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: World Triathlon Edmonton, Mitacs.
Abstract (Originalsprache)
Determining an athlete’s maximal peak power (MPP) is crucial in profiling endurance sports participants. While short (3 to 6 seconds) all-out efforts have been validated for MPP assessment, prior studies mainly involved non-endurance trained athletes. This study aimed to assess the intra- and inter-day reliability of a 6-second Wingate test for MPP determination in endurance athletes. Endurance-trained participants (22 males, 5 females) completed nine 6-second Wingate tests over four days (3 trials at baseline, 2 trials on each subsequent day). Analysis revealed no systematic differences in MPP (F(4.09, 106.3) = 1.88, p = 0.117) or time to peak power (χ 2 (8) = 5.23, p = 0.732) across the trials. Reliability, assessed through the intraclass correlation coefficient (ICC) and standard error of measurement (SEM), was excellent across all trials (ICC = 0.95, SEM = 40.0W, SEM% = 3.7%). Absolute reliability improved when selecting the average or the best MPP values from each day (SEM% = 2.7% and 2.9%, respectively). Within-day reliability was consistently rated as excellent, with the best values on the 4 th day of tests. No significant differences in MPP values occurred between the first and second 6-second Wingate tests on days 1 to 3, with both trials demonstrating similar reliability values (SEM%: 3.2% vs 2.8%, for the first and second trials, respectively). The test also demonstrated a good sensitivity to detect a meaningful change in MPP values. In conclusion, the 6-second Wingate test proves reliable for determining MPP in endurance-trained athletes. Two trials are recommended on the first day of testing, with a single MPP likely sufficient to determine the athlete’s MPP on subsequent days.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Faculty of Kinesiology, Sport and Recreation, University of Alberta, Edmonton, Alberta, Canada.
- Alberta Diabetes Institute, University of Alberta, Edmonton, Canada.
- Neuroscience and Mental Health Institute, Edmonton, Alberta, Canada.
ORCID-Profile: Joao Henrique Falk Neto, Kelvin E Jones, Aidan K Comeau
Förderung
- World Triathlon Edmonton
- Mitacs
Zitieren
APA
Falk Neto, J. H., Boulé, N., Jones, K. E., Comeau, A. K., & Kennedy, M. D. (2024). The intra-day and inter-day reliability of a 6-second Wingate to determine maximal peak power in endurance-trained athletes. PLOS ONE, 19(9), e0307325. https://doi.org/10.1371/journal.pone.0307325
Vancouver
Falk Neto JH, Boulé N, Jones KE, Comeau AK, Kennedy MD. The intra-day and inter-day reliability of a 6-second Wingate to determine maximal peak power in endurance-trained athletes. PLOS ONE. 2024;19(9):e0307325. doi:10.1371/journal.pone.0307325
BibTeX
@article{FalkNeto2024,
author = {Falk Neto, Joao Henrique and Boulé, Normand and Jones, Kelvin E and Comeau, Aidan K and Kennedy, Michael D},
title = {The intra-day and inter-day reliability of a 6-second Wingate to determine maximal peak power in endurance-trained athletes},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {9},
pages = {e0307325},
doi = {10.1371/journal.pone.0307325}
}
EUVIMED