EUVIMEDEUVIMED entdecken
Crossref

Determination of Ventilatory Thresholds Using Near-Infrared Spectroscopy in Recreational Endurance and CrossFit Athletes

Janik Arnet, Raphael Knaier iD, Raphael Schoch iD, Gommaar D'Hulst iD, Fabienne Bruggisser iD, Andri Feldmann iD, Rahel Leuenberger, Elena Westerhuis, Denis Infanger iD, Arno Schmidt-Trucksäss iD, Jonathan Wagner iD

International Journal of Sports Physiology and Performance · 2025

DOI: 10.1123/ijspp.2024-0265 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Sports Physiology and Performance, 2025. Verfasst von Janik Arnet und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sport, Exercise and Health, Faculty of Medicine, University of Basel, Basel, Switzerland. Hauptthemen laut MEDLINE: Anaerobic Threshold, Muscle, Skeletal, Physical Endurance. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To define training zones, ventilatory thresholds (VTs) are commonly established by cardiopulmonary gas-exchange analysis during incremental exercise tests. Portable near-infrared spectroscopy (NIRS) devices have emerged as a potential tool for detecting these thresholds by monitoring muscle oxygenation. This study evaluated the accuracy of NIRS measurements to determine VTs or critical power (CP) based on muscle oxygen saturation and assesses the device’s consistency across 2 constant-load tests. Data from 2 cross-sectional studies involving trained recreational endurance athletes (26 from study 1) and CrossFit athletes (59 from study 2) were examined. Incremental ramp tests on a cycle ergometer were performed and followed by either a constant-load test (study 1) or a CP test (study 2). When comparing power output or heart rate between NIRS-derived breakpoints and VTs, weak to moderate agreement was found. Mean differences in power output and heart rate ranged from 16.8 to 22.4 W and 3.8 to 6.0 beats·min −1 at the first threshold and 27.4 to 31.2 W and 7.1 to 7.8 beats·min −1 at the second threshold. Comparing with CP, mean differences ranged from −0.4 to 0.4 W and −0.6 to 0.9 beats·min −1 . Test–retest reliability showed moderate agreement, with a mean bias of 1.2 percentage points between constant-load tests. Thus, NIRS may not be accurate for determining VTs or CP during exercise due to limited agreement in power output or hear rate, notable variability on individual level, and moderate reproducibility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anaerobic ThresholdMuscle, SkeletalPhysical EnduranceHumansSpectroscopy, Near-InfraredMaleCross-Sectional StudiesExercise TestHeart RateAdultReproducibility of ResultsYoung AdultFemaleOxygen ConsumptionAthletesOxygen Saturation

Stichwörter der Autor:innen

NIRScritical powerfitness testingtraining zoneswearables

Autor:innen und Institutionen

  • Department of Sport, Exercise and Health, Faculty of Medicine, University of Basel, Basel, Switzerland.
  • Health Sciences and Technology, Swiss Federal Institute of Technology (ETH) Zurich, Zurich, Switzerland.
  • Institute of Sport Science, University of Bern, Bern, Switzerland.

ORCID-Profile: Raphael Knaier, Raphael Schoch, Gommaar D'Hulst, Fabienne Bruggisser, Andri Feldmann, Denis Infanger, Arno Schmidt-Trucksäss, Jonathan Wagner

Zitieren

APA

Arnet, J., Knaier, R., Schoch, R., D'Hulst, G., Bruggisser, F., Feldmann, A., Leuenberger, R., Westerhuis, E., Infanger, D., Schmidt-Trucksäss, A., & Wagner, J. (2025). Determination of Ventilatory Thresholds Using Near-Infrared Spectroscopy in Recreational Endurance and CrossFit Athletes. International Journal of Sports Physiology and Performance. https://doi.org/10.1123/ijspp.2024-0265

Vancouver

Arnet J, Knaier R, Schoch R, D'Hulst G, Bruggisser F, Feldmann A, et al. Determination of Ventilatory Thresholds Using Near-Infrared Spectroscopy in Recreational Endurance and CrossFit Athletes. International Journal of Sports Physiology and Performance. 2025. doi:10.1123/ijspp.2024-0265

BibTeX
@article{Arnet2025,
  author = {Arnet, Janik and Knaier, Raphael and Schoch, Raphael and D'Hulst, Gommaar and Bruggisser, Fabienne and Feldmann, Andri and Leuenberger, Rahel and Westerhuis, Elena and Infanger, Denis and Schmidt-Trucksäss, Arno and Wagner, Jonathan},
  title = {Determination of Ventilatory Thresholds Using Near-Infrared Spectroscopy in Recreational Endurance and CrossFit Athletes},
  journal = {International Journal of Sports Physiology and Performance},
  year = {2025},
  doi = {10.1123/ijspp.2024-0265}
}
Kostenlos starten →