Performance evaluation of Rayto RT-7600Vet hematology analyzer in side-by-side comparison with manual hematological methods for apparently healthy Cholistani cattle blood

Umer Farooq iD, Mushtaq Hussain Lashari, Zia Ur Rehman, Musadiq Idris, Haroon Rashid, Shagufta Nasreen, Farah Laraib, Rubaisha Ameer, Maryam Chauhdary, Iram Fatima

PLOS ONE · 2025

DOI: 10.1371/journal.pone.0302617 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift PLOS ONE, 2025. Verfasst von Umer Farooq und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiology, The Islamia University of Bahawalpur, Bahawalpur, Pakistan. Hauptthemen laut MEDLINE: Hematologic Tests, Hematology. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The present study is the first from Pakistan being reported with an objective to assess performance of Rayto RT-7600Vet hematology analyzer (HA) for Cholistani cattle blood (n = 134), in comparison to the manual hematological methods. The four hematological attributes viz . total erythrocyte count (TEC), hemoglobin (Hb), packed cell volume (PCV) and platelet count (PLT) were deduced through HA (A) and manual (M) methods. Various statistical tests were implied to ascertain level of interrelationship, accuracy and level of agreement between the two methods. All attributes attained through manual methods had high positive, leptokurtic distribution (having many outliers) except for PLT-M and PCV-M. The coefficient of variation for attributes attained through HA and manual methods ranged from 16–24% and from 16–59%, respectively. Comparison between the overall results revealed that all the studied attributes, except TEC, were significantly (P≤0.05) different for both methods. A weak relationship was noticed between the attributes attained through two methods as indicated by weak r-values and adjusted r-square values. The reliability level of estimating Hb and PCV had highest intraclass correlation coefficient value of 0.722 and 0.555 for average measures, respectively. However, accuracy level, as determined through Lin’s concordance correlation coefficient was highest for TEC (0.9504) for both analytical methods. Poor level of agreement, in general, was shown for the two methods of analysis regarding all four hematological attributes through Bland and Altman test. In conclusion, the Rayto RT-7600Vet) may present data having higher skewness, kurtosis, and CV%, however, they are valid for multi-species hematological analysis. Caution must however, be taken in interpreting their results with corrected reference intervals and CV% for each machine and for each tested attribute.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hematologic TestsHematologyAnimalsCattleHemoglobinsReproducibility of ResultsErythrocyte CountHematocritPlatelet CountPakistan

Substanzen

Hemoglobins

Autor:innen und Institutionen

  • Department of Physiology, The Islamia University of Bahawalpur, Bahawalpur, Pakistan.
  • Department of Zoology, The Islamia University of Bahawalpur, Bahawalpur, Pakistan.

ORCID-Profile: Umer Farooq

Zitieren

APA

Farooq, U., Lashari, M. H., Rehman, Z. U., Idris, M., Rashid, H., Nasreen, S., Laraib, F., Ameer, R., Chauhdary, M., & Fatima, I. (2025). Performance evaluation of Rayto RT-7600Vet hematology analyzer in side-by-side comparison with manual hematological methods for apparently healthy Cholistani cattle blood. PLOS ONE. https://doi.org/10.1371/journal.pone.0302617

Vancouver

Farooq U, Lashari MH, Rehman ZU, Idris M, Rashid H, Nasreen S, et al. Performance evaluation of Rayto RT-7600Vet hematology analyzer in side-by-side comparison with manual hematological methods for apparently healthy Cholistani cattle blood. PLOS ONE. 2025. doi:10.1371/journal.pone.0302617

BibTeX
@article{Farooq2025,
  author = {Farooq, Umer and Lashari, Mushtaq Hussain and Rehman, Zia Ur and Idris, Musadiq and Rashid, Haroon and Nasreen, Shagufta and Laraib, Farah and Ameer, Rubaisha and Chauhdary, Maryam and Fatima, Iram},
  title = {Performance evaluation of Rayto RT-7600Vet hematology analyzer in side-by-side comparison with manual hematological methods for apparently healthy Cholistani cattle blood},
  journal = {PLOS ONE},
  year = {2025},
  doi = {10.1371/journal.pone.0302617}
}
Kostenlos starten →