Agreement of Hematologic Measurements Between Jugular and Coccygeal Puncture Sites in Cattle
Veterinary Clinical Pathology · 2026-09 · 55 (3) · 295-303
DOI: 10.1111/vcp.70144 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Clinical Pathology, online erschienen am 13.08.2026. Verfasst von Sophie Clouard und 2 weiteren Autor:innen. Beteiligte Einrichtung: VetAgro Sup, Lyon, France. Hauptthemen laut MEDLINE: Jugular Veins, Punctures, Hematologic Tests, Phlebotomy. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: VetAgro Sup.
Abstract (Originalsprache)
Background
In bovine medicine, venipuncture is commonly performed at either the jugular or coccygeal vein. Although the coccygeal site is often preferred for practical reasons, sampling sites are inconsistently standardized in scientific studies. It is therefore important to determine whether hematologic values obtained from these two sites can be considered interchangeable.
Objectives
To evaluate the statistical and clinical concordance of hematologic measurands obtained from paired jugular and coccygeal blood samples in cattle.
Methods
Paired jugular and coccygeal blood samples were collected from 48 adult cows and analyzed using an automated hematology analyzer, micro‐hematocrit determination, and blood smear evaluation. Agreement between sites was assessed using Pearson and Lin's correlation coefficients, Passing–Bablok regression, and Bland–Altman analysis, with clinical relevance evaluated against published total allowable error (TEa) thresholds.
Results
Most hematologic measurands showed good agreement between jugular and coccygeal sampling sites. However, platelet counts, packed cell volume (PCV), and certain manual leukocyte differential counts on blood smears, particularly neutrophils and lymphocytes, demonstrated poorer agreement and should not be considered interchangeable.
Conclusions
Jugular and coccygeal puncture sites yield largely comparable hematologic results for most automated measurands. However, platelet indices, packed cell volume, and manual leukocyte differentials on blood smears, particularly neutrophils and lymphocytes, show greater variability between sites and should not be considered interchangeable. In clinical settings, when results are compared with reference intervals or used for longitudinal monitoring, consistent use and documentation of the puncture site are recommended, and reference intervals established using the same sampling site should be applied for these variables.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- VetAgro Sup, Lyon, France.
- Laboratoire Physiopathologie et Génétique du Neurone et du Muscle (PGNM), Institut NeuroMyoGène, INSERM U1315, CNRS UMR 5261, Université Claude Bernard Lyon 1, Lyon, France.
ORCID-Profile: Thomas Chetot
Förderung
- VetAgro Sup
Zitieren
APA
Clouard, S., Remuzat, C., & Chetot, T. (2026). Agreement of Hematologic Measurements Between Jugular and Coccygeal Puncture Sites in Cattle. Veterinary Clinical Pathology, 55(3), 295-303. https://doi.org/10.1111/vcp.70144
Vancouver
Clouard S, Remuzat C, Chetot T. Agreement of Hematologic Measurements Between Jugular and Coccygeal Puncture Sites in Cattle. Veterinary Clinical Pathology. 2026;55(3):295-303. doi:10.1111/vcp.70144
BibTeX
@article{Clouard2026,
author = {Clouard, Sophie and Remuzat, Camille and Chetot, Thomas},
title = {Agreement of Hematologic Measurements Between Jugular and Coccygeal Puncture Sites in Cattle},
journal = {Veterinary Clinical Pathology},
year = {2026},
volume = {55},
number = {3},
pages = {295--303},
doi = {10.1111/vcp.70144}
}
EUVIMED