EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Small design modifications can improve the primary stability of a fully coated tapered wedge hip stem

Katja Glismann iD, Tobias Konow, Frank Lampe, Benjamin Ondruschka, Gerd Huber, Michael M Morlock

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0300956 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Katja Glismann und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomechanics, TUHH Hamburg University of Technology, Hamburg, Germany. Hauptthemen laut MEDLINE: Hip Prosthesis, Periprosthetic Fractures, Arthroplasty, Replacement, Hip. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Increasing the stem size during surgery is associated with a higher incidence of intraoperative periprosthetic fractures in cementless total hip arthroplasty with fully coated tapered wedge stems, especially in femurs of Dorr type A. If in contrast a stem is implanted and sufficient primary stability is not achieved, such preventing successful osseointegration due to increased micromotions, it may also fail, especially if the stem is undersized. Stem loosening or periprosthetic fractures due to stem subsidence can be the consequence. The adaptation of an established stem design to femurs of Dorr type A by design modifications, which increase the stem width proximally combined with a smaller stem tip and an overall shorter stem, might reduce the risk of distal locking of a proximally inadequately fixed stem and provide increased stability. The aim of this study was to investigate whether such a modified stem design provides improved primary stability without increasing the periprosthetic fracture risk compared to the established stem design. The established (Corail, DePuy Synthes, Warsaw, IN, US) and modified stem designs (Emphasys, DePuy Synthes, Warsaw, IN, US) were implanted in cadaveric femur pairs (n = 6 pairs) using the respective instruments. Broaching and implantation forces were recorded and the contact areas between the prepared cavity and the stem determined. Implanted stems were subjected to two different cyclic loading conditions according to ISO 7206–4 using a material testing machine (1 Hz, 600 cycles @ 80 to 800 N, 600 cycles @ 80 to 1600 N). Translational and rotational relative motions between stem and femur were recorded using digital image correlation. Broaching and implantation forces for the modified stem were up to 40% higher (p = 0.024), achieving a 23% larger contact area between stem and bone (R 2 = 0.694, p = 0.039) resulting in a four times lower subsidence during loading (p = 0.028). The slight design modifications showed the desired effect in this in-vitro study resulting in a higher primary stability suggesting a reduced risk of loosening. The higher forces required during the preparation of the cavity with the new broaches and during implantation of the stem could bare an increased risk for intraoperative periprosthetic fractures, which did not occur in this study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hip ProsthesisPeriprosthetic FracturesArthroplasty, Replacement, HipHumansProsthesis DesignOsseointegrationFemurReoperationRetrospective Studies

Autor:innen und Institutionen

  • Institute of Biomechanics, TUHH Hamburg University of Technology, Hamburg, Germany.
  • Asklepios Klinik Barmbek, Hamburg, Germany.
  • Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.

ORCID-Profile: Katja Glismann

Zitieren

APA

Glismann, K., Konow, T., Lampe, F., Ondruschka, B., Huber, G., & Morlock, M. M. (2024). Small design modifications can improve the primary stability of a fully coated tapered wedge hip stem. PLOS ONE. https://doi.org/10.1371/journal.pone.0300956

Vancouver

Glismann K, Konow T, Lampe F, Ondruschka B, Huber G, Morlock MM. Small design modifications can improve the primary stability of a fully coated tapered wedge hip stem. PLOS ONE. 2024. doi:10.1371/journal.pone.0300956

BibTeX
@article{Glismann2024,
  author = {Glismann, Katja and Konow, Tobias and Lampe, Frank and Ondruschka, Benjamin and Huber, Gerd and Morlock, Michael M},
  title = {Small design modifications can improve the primary stability of a fully coated tapered wedge hip stem},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0300956}
}
Kostenlos starten →