EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Vancouver type B2 periprosthetic femoral fractures: clinical and radiological outcomes from a tertiary care center

Stefano Tornago, Luca Cavagnaro, Lorenzo Mosconi, Francesco Chiarlone, Andrea Zanirato, Nicolò Patroniti, Matteo Formica

Archives of Orthopaedic and Trauma Surgery · 01.07.2023 · 143 (11) · 6919-6926

DOI: 10.1007/s00402-023-04955-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, online erschienen am 01.07.2023. Verfasst von Stefano Tornago und 6 weiteren Autor:innen. Beteiligte Einrichtung: Joint Replacement Unit, Ortopedia e Traumatologia 2, Ospedale Santa Corona, Viale 25 Aprile, 38, 17027, Pietra Ligure, SV, Italy. Hauptthemen laut MEDLINE: Periprosthetic Fractures, Arthroplasty, Replacement, Hip, Femoral Fractures, Hip Prosthesis. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università degli Studi di Genova.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The purpose of this study was to report mid-term clinical and radiographic results after hip arthroplasty revision in Vancouver type B2 femoral periprosthetic fractures (PPFx). Specifical focus of the paper is as follows: (1) the description of a standardized and reproducible surgical technique, (2) functional outcomes presentation and (3) type and number of complications and implants’ survival rate analysis.

Methods

We retrospectively reviewed all patients treated for hip revision with non-modular tapered fluted titanium stem in patients with Vancouver type B2 femur PPFx at a single institution. At least 18 months’ follow-up period was required. Harris Hip Scores and SF-12 were obtained, and radiographical follow-up was performed. Complications were reported and analyzed.

Results

The authors included 114 patients (114 hips) with a mean follow-up of 62.8 ± 30.6 months. All patients were treated with Wagner SL revision hip stem (Zimmer-Biomet), metal cerclage wires ± trochanteric plate. The mean HHS and SF-12 score at the last follow-up evaluation were respectively 81.3 ± 9.7 and 32.5 ± 7.6. Seventeen (14.9%) complications occurred. We observed five cases of dislocations, two of periprosthetic joint infections and six cases of new PPFx. The stem-related revision rate for any cause at the final FU was 1.7%, due to PJI. No patients underwent stem revision surgery for aseptic loosening. Fracture healed in all the included patients with a union-rate of 100%. The re-operation rate for any cause was 9.6%, with an implant survival rate for overall failure of 96.5%.

Conclusion

The presented standard and reproducible surgical technique obtains optimal clinical and radiological results with limited complication rate at mid-term follow up. Preoperative planning as well as careful intraoperative surgical technique is of a paramount importance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Periprosthetic FracturesArthroplasty, Replacement, HipFemoral FracturesHip ProsthesisHumansRetrospective StudiesTertiary Care CentersFemurReoperationProsthesis DesignTreatment Outcome

Stichwörter der Autor:innen

Hip revisionOutcomesPeriprosthetic fractureSurgical techniqueTotal hip arthroplasty

Autor:innen und Institutionen

  • Joint Replacement Unit, Ortopedia e Traumatologia 2, Ospedale Santa Corona, Viale 25 Aprile, 38, 17027, Pietra Ligure, SV, Italy.
  • Joint Replacement Unit, Ortopedia e Traumatologia 2, Ospedale Santa Corona, Viale 25 Aprile, 38, 17027, Pietra Ligure, SV, Italy. lucacavagnaro87@gmail.com.
  • UO 1' Sezione di Ortopedia e Traumatologia, Istituto Clinico San Rocco Gruppo San Donato, Via dei Sabbioni, 24, BS, 25050, Ome, Italy.
  • Policlinico San Martino, Clinica Ortopedica, Largo Rosanna Benzi 10, 16132, Genoa, GE, Italy.
  • DISC, Dipartimento di Scienze Chirurgiche e Diagnostiche Integrate, Viale Benedetto XV 6, 16132, Genoa, GE, Italy.
  • Anesthesia and Intensive Care Unit, Ospedale Santa Corona, Viale 25 Aprile, 38, 17027, Pietra Ligure, SV, Italy.

Förderung

  • Università degli Studi di Genova

Zitieren

APA

Tornago, S., Cavagnaro, L., Mosconi, L., Chiarlone, F., Zanirato, A., Patroniti, N., & Formica, M. (2023). Vancouver type B2 periprosthetic femoral fractures: clinical and radiological outcomes from a tertiary care center. Archives of Orthopaedic and Trauma Surgery, 143(11), 6919-6926. https://doi.org/10.1007/s00402-023-04955-2

Vancouver

Tornago S, Cavagnaro L, Mosconi L, Chiarlone F, Zanirato A, Patroniti N, et al. Vancouver type B2 periprosthetic femoral fractures: clinical and radiological outcomes from a tertiary care center. Archives of Orthopaedic and Trauma Surgery. 2023;143(11):6919-6926. doi:10.1007/s00402-023-04955-2

BibTeX
@article{Tornago2023,
  author = {Tornago, Stefano and Cavagnaro, Luca and Mosconi, Lorenzo and Chiarlone, Francesco and Zanirato, Andrea and Patroniti, Nicolò and Formica, Matteo},
  title = {Vancouver type B2 periprosthetic femoral fractures: clinical and radiological outcomes from a tertiary care center},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2023},
  volume = {143},
  number = {11},
  pages = {6919--6926},
  doi = {10.1007/s00402-023-04955-2}
}
Kostenlos starten →