EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improving the reliability of underwater gait analysis using wearable pressure and inertial sensors

Cecilia Monoli iD, Manuela Galli, Jeffrey A Tuhtan iD

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0300100 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Cecilia Monoli und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Systems, Tallinn University of Technology, Tallinn, Estonia. Hauptthemen laut MEDLINE: Gait Analysis, Wearable Electronic Devices. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Estonian Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This work addresses the lack of reliable wearable methods to assess walking gaits in underwater environments by evaluating the lateral hydrodynamic pressure exerted on lower limbs. Sixteen healthy adults were outfitted with waterproof wearable inertial and pressure sensors. Gait analysis was conducted on land in a motion analysis laboratory using an optoelectronic system as reference, and subsequently underwater in a rehabilitation swimming pool. Differences between the normalized land and underwater gaits were evaluated using temporal gait parameters, knee joint angles and the total water pressure on the lower limbs. The proposed method was validated against the optoelectronic system on land; gait events were identified with low bias (0.01s) using Bland-Altman plots for the stride time, and an acceptable error was observed when estimating the knee angle (10.96° RMSE, Bland-Altman bias -2.94°). The kinematic differences between the land and underwater environments were quantified, where it was observed that the temporal parameters increased by more than a factor of two underwater (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Gait AnalysisWearable Electronic DevicesAdultHumansReproducibility of ResultsGaitWalkingBiomechanical PhenomenaWater

Substanzen

Water

Autor:innen und Institutionen

  • Department of Computer Systems, Tallinn University of Technology, Tallinn, Estonia.
  • Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.

ORCID-Profile: Cecilia Monoli, Jeffrey A Tuhtan

Förderung

  • Estonian Research Council

Zitieren

APA

Monoli, C., Galli, M., & Tuhtan, J. A. (2024). Improving the reliability of underwater gait analysis using wearable pressure and inertial sensors. PLOS ONE. https://doi.org/10.1371/journal.pone.0300100

Vancouver

Monoli C, Galli M, Tuhtan JA. Improving the reliability of underwater gait analysis using wearable pressure and inertial sensors. PLOS ONE. 2024. doi:10.1371/journal.pone.0300100

BibTeX
@article{Monoli2024,
  author = {Monoli, Cecilia and Galli, Manuela and Tuhtan, Jeffrey A},
  title = {Improving the reliability of underwater gait analysis using wearable pressure and inertial sensors},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0300100}
}
Kostenlos starten →