EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effective volume of rebreathed air during breathing with facepieces increases with protection class and decreases with ambient airflow

Helen Ngo, Johannes Spaeth, Stefan Schumann iD

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0299919 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Helen Ngo und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Department of Anesthesiology and Critical Care, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany. Hauptthemen laut MEDLINE: Respiratory Protective Devices. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearing facepieces is discussed in the context of increasing the volume of rebreathed air. We hypothesized that rebreathed air volume increases with increasing filtering facepiece (FFP) class and that persons breathing via facepieces compensate for the additional dead-space. We have determined the effective amount of rebreathed air for a surgical masks and FFP2 and FFP3 respirators in a physical model and determined tidal volumes, breathing frequency, blood oxygen saturation, and transcutaneously measured blood carbon dioxide partial pressure (PCO 2 ) in lung-healthy subjects breathing without and with facepieces at rest and during exercising on a recumbent ergometer. Rebreathed air volume increased with the facepieces’ protection class and with increasing inspiration volume by 45 ± 2 ml to 247 ± 1 ml. Ambient airflow reduced rebreathed air volume by 17% up to 100% (all p < 0.001). When wearing facepieces, subjects increased tidal volume (p < 0.001) but not breathing frequency. Oxygen saturation was not influenced by facepieces. With FFP3 respirators PCO 2 increased by up to 3.2 mmHg (p < 0.001) at rest but only up to 1.4 mmHg (p < 0.001) when exercising. Discomfort of breathing increased with increasing protection class of the facepiece but was consistently perceived as tolerable. We conclude that the amount of rebreathed air increases with increasing protection class of facepieces. Healthy adults were capable to compensate the facepieces’ dead-space by adapting tidal volume at rest and during physical activity; thereby they tolerated moderate increases in PCO 2 . Ambient airflow may considerably reduce the amount of facepiece related rebreathed air.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Respiratory Protective DevicesAdultHumansRespirationTidal VolumeExerciseLung

Autor:innen und Institutionen

  • Faculty of Medicine, Department of Anesthesiology and Critical Care, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany.

ORCID-Profile: Stefan Schumann

Zitieren

APA

Ngo, H., Spaeth, J., & Schumann, S. (2024). Effective volume of rebreathed air during breathing with facepieces increases with protection class and decreases with ambient airflow. PLOS ONE. https://doi.org/10.1371/journal.pone.0299919

Vancouver

Ngo H, Spaeth J, Schumann S. Effective volume of rebreathed air during breathing with facepieces increases with protection class and decreases with ambient airflow. PLOS ONE. 2024. doi:10.1371/journal.pone.0299919

BibTeX
@article{Ngo2024,
  author = {Ngo, Helen and Spaeth, Johannes and Schumann, Stefan},
  title = {Effective volume of rebreathed air during breathing with facepieces increases with protection class and decreases with ambient airflow},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0299919}
}
Kostenlos starten →