Facial electromyography during exercise using soft electrode array: A feasibility study
PLOS ONE · 15.02.2024 · 19 (2) · e0298304
DOI: 10.1371/journal.pone.0298304 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 15.02.2024. Verfasst von Rawan Ibrahim und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel. Hauptthemen laut MEDLINE: Quadriceps Muscle, Facial Muscles. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Israel Science Foundation, Israel Defense Forces (IDF) Medical Corps and Directorate of Defense Research & Development, Israeli Ministry of Defense.
Abstract (Originalsprache)
The use of wearable sensors for real-time monitoring of exercise-related measures has been extensively studied in recent years (e.g., performance enhancement, optimizing athlete’s training, and preventing injuries). Surface electromyography (sEMG), which measures muscle activity, is a widely researched technology in exercise monitoring. However, due to their cumbersome nature, traditional sEMG electrodes are limited. In particular, facial EMG (fEMG) studies in physical training have been limited, with some scarce evidence suggesting that fEMG may be used to monitor exercise-related measurements. Altogether, sEMG recordings from facial muscles in the context of exercise have been examined relatively inadequately. In this feasibility study, we assessed the ability of a new wearable sEMG technology to measure facial muscle activity during exercise. Six young, healthy, and recreationally active participants (5 females), performed an incremental cycling exercise test until exhaustion, while facial sEMG and vastus lateralis (VL) EMG were measured. Facial sEMG signals from both natural expressions and voluntary smiles were successfully recorded. Stable recordings and high-resolution facial muscle activity mapping were achieved during different exercise intensities until exhaustion. Strong correlations were found between VL and multiple facial muscles’ activity during voluntary smiles during exercise, with statistically significant coefficients ranging from 0.80 to 0.95 (p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel.
- Medical Corps, Israel Defense Forces, Ramat Gan, Israel.
- Sylvan Adams Sports Institute, School of Public Health, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel.
- Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel.
- X-trodes, Herzelia, Israel.
ORCID-Profile: Rawan Ibrahim, Yael Hanein
Förderung
- Israel Science Foundation
- Israel Defense Forces (IDF) Medical Corps and Directorate of Defense Research & Development, Israeli Ministry of Defense
Zitieren
APA
Ibrahim, R., Ketko, I., Scheinowitz, M., & Hanein, Y. (2024). Facial electromyography during exercise using soft electrode array: A feasibility study. PLOS ONE, 19(2), e0298304. https://doi.org/10.1371/journal.pone.0298304
Vancouver
Ibrahim R, Ketko I, Scheinowitz M, Hanein Y. Facial electromyography during exercise using soft electrode array: A feasibility study. PLOS ONE. 2024;19(2):e0298304. doi:10.1371/journal.pone.0298304
BibTeX
@article{Ibrahim2024,
author = {Ibrahim, Rawan and Ketko, Itay and Scheinowitz, Mickey and Hanein, Yael},
title = {Facial electromyography during exercise using soft electrode array: A feasibility study},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {2},
pages = {e0298304},
doi = {10.1371/journal.pone.0298304}
}
EUVIMED