EUVIMEDEUVIMED entdecken
BeobachtungsstudieVergleichsstudie

Feasibility of Cricothyroid Muscle Needle Electrode for Monitored Thyroidectomy

Wen Liang Joel Lau iD, Che-Wei Wu iD, Man Hon Tang, Han Boon Oh, Wei Keat Cheah, Moon Young Oh iD, Young Jun Chai

The Laryngoscope · 2025

DOI: 10.1002/lary.32051 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift The Laryngoscope, 2025. Verfasst von Wen Liang Joel Lau und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Head and Neck Surgery, Division of Surgery and Surgical Oncology, Singapore General Hospital, National Cancer Centre Singapore, Singapo…. Hauptthemen laut MEDLINE: Electromyography, Laryngeal Muscles, Monitoring, Intraoperative, Recurrent Laryngeal Nerve Injuries. Die Arbeit nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Preservation of the recurrent laryngeal nerve (RLN) and external branch of the superior laryngeal nerve (EBSLN) is essential to maintain voice function after thyroidectomy. Intraoperative neuromonitoring (IONM) assists in nerve preservation. This study compares three IONM modalities, endotracheal surface electrode (ETSE), thyroid cartilage needle electrodes (TCNE), and cricothyroid muscle needle electrode (CTNE), in their monitoring of laryngeal muscle electromyographic (EMG) amplitude.

Methods

An observational prospective cohort study included 29 patients ( 21F : 8M ) undergoing thyroidectomy for Bethesda III – VI nodules or benign nodules >4 cm. EMG amplitudes were recorded via ETSE , TCNE , and CTNE following stimulation of the EBSLN , RLN , and vagus nerve ( VN) .

Results

A total of 105 nerves at risk were assessed, including 35 EBSLNs, 35 VNs, and 35 RLNs. The recorded amplitudes at S1 for the ETSE, TCNE, and CTNE were 45.6 ± 60.7 μV, 403.7 ± 865.4 μV, and 3049.4 ± 2749.8 μV. The CTNE demonstrate significantly higher S1 amplitudes and positive signal rates compared with both the TCNE and ETSE (p < 0.001). For V1, the recorded amplitudes for the ETSE, TCNE, and CTNE were 453.7 ± 406.7 μV, 1363.9 ± 1063.6 μV, and 700 ± 375.1 μV. For R1, the recorded amplitudes for the ETSE, TCNE, and CTNE were 567.1 ± 556 μV, 1544.6 ± 1269.6 μV, and 720.4 ± 363.1 μV. With a threshold of 100 μV to determine positive signal, CTNE detected all EBSLN, VN, and RLN signals, whereas TC missed 13 cases (37.1%) of EBSLN.

Conclusion

The CTNE showed a higher positive signal rate than ETSE and TCNE in detection of EBSLN, whereas it showed similar performance with TCNE in detection of VN and RLN. CTNE is a viable option for IONM during thyroidectomy. Level of Evidence 2 Laryngoscope , 135:1843–1849, 2025

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectromyographyLaryngeal MusclesMonitoring, IntraoperativeRecurrent Laryngeal Nerve InjuriesThyroidectomyAdultAgedFemaleHumansMaleMiddle AgedElectrodesFeasibility StudiesNeedlesProspective Studies

Stichwörter der Autor:innen

electromyographyneural monitoringrecurrent laryngeal nervethyroid surgery

Autor:innen und Institutionen

  • Department of Head and Neck Surgery, Division of Surgery and Surgical Oncology, Singapore General Hospital, National Cancer Centre Singapore, Singapore, Singapore.
  • Department of Otorhinolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, School of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan.
  • Department of Surgery, Division of Head and Neck and Endocrine Surgery, Woodlands Health, National Healthcare Group, Singapore, Singapore.
  • Department of Surgery, Division of Breast and Endocrine Surgery, Ng Teng Fong General Hospital, National University Health System, Singapore, Singapore.
  • Department of Surgery, Seoul National University College of Medicine, Seoul Metropolitan Government Seoul National University Boramae Medical Center, Seoul, Korea.
  • Transdisciplinary Department of Medicine & Advanced Technology, Seoul National University Hospital, Seoul, Korea.

ORCID-Profile: Wen Liang Joel Lau, Che-Wei Wu, Moon Young Oh

Zitieren

APA

Lau, W. L. J., Wu, C. W., Tang, M. H., Oh, H. B., Cheah, W. K., Oh, M. Y., & Chai, Y. J. (2025). Feasibility of Cricothyroid Muscle Needle Electrode for Monitored Thyroidectomy. The Laryngoscope. https://doi.org/10.1002/lary.32051

Vancouver

Lau WLJ, Wu CW, Tang MH, Oh HB, Cheah WK, Oh MY, et al. Feasibility of Cricothyroid Muscle Needle Electrode for Monitored Thyroidectomy. The Laryngoscope. 2025. doi:10.1002/lary.32051

BibTeX
@article{Lau2025,
  author = {Lau, Wen Liang Joel and Wu, Che-Wei and Tang, Man Hon and Oh, Han Boon and Cheah, Wei Keat and Oh, Moon Young and Chai, Young Jun},
  title = {Feasibility of Cricothyroid Muscle Needle Electrode for Monitored Thyroidectomy},
  journal = {The Laryngoscope},
  year = {2025},
  doi = {10.1002/lary.32051}
}
Kostenlos starten →