EUVIMEDEUVIMED entdecken
MetaanalyseSystematische ÜbersichtOpen Access · CC BY 4.0

How to choose the intraocular lens power calculation formulas in eyes with extremely long axial length? A systematic review and meta-analysis

Xiaoyu Li iD, Xiaodong Wang, Xuan Liao iD

PLOS ONE · 22.01.2024 · 19 (1) · e0296771

DOI: 10.1371/journal.pone.0296771 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift PLOS ONE, online erschienen am 22.01.2024. Verfasst von Xiaoyu Li und 2 weiteren Autor:innen. Beteiligte Einrichtung: Nanchong Central Hospital, The Second Clinical College, North Sichuan Medical College, Nanchong, China. Hauptthemen laut MEDLINE: Cataract, Cataract Extraction, Lenses, Intraocular. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Project of the National Natural Science Foundation of Sichuan Provincial Department of Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the accuracy of 10 formulas for calculating intraocular lens (IOL) power in cataract eye with an axial length (AL) of more than 28.0 mm.

Methods

We searched scientific databases including PubMed, EMBASE, Web of Science and Cochrane Library for research published over the past 5 years, up to Sept 2023. The inclusion criteria were case series studies that compared different formulas (Barrett II, EVO, Kane, Hill-RBF, Haigis, Hoffer Q, Holladay 1, SRK/T, Holladay 1 w-k and SRK/T w-k), in patients with extremely long AL undergoing uncomplicated cataract surgery with IOL implantation. The mean difference (MD) of mean absolute error (MAE) and the odds ratio (OR) of both the percentage of eyes within ±0.50D of prediction error (PPE±0.50D) and the percentage of eyes within ±1.00D of prediction error (PPE±1.00D) among different formulas were pooled using meta-analysis.

Results

A total of 11 studies, involving 1376 eyes, were included to evaluate the 10 formulas mentioned above. Among these formulas, Barrett II, EVO, Kane, and Hill-RBF demonstrated significantly lower MAE values compared to SRK/T. Furthermore, Kane and Hill-RBF had lower MAE values than EVO. Additionally, Barrett II and Kane yielded significantly lower MAE values than Haigis while Hill-RBF showed significantly lower MAE values than Holladay 1. Moreover, Hill-RBF showed the highest values for both PPE±0.50D and PPE±1.00D, followed by Kane. Both EVO and Kane had higher values of PPE±0.50D and PPE±1.00D compared to Haigis and SRK/T.

Conclusion

The Wang-Koch adjusted formulas and new-generation formulas have shown potential for higher accuracy in predicting IOL power for cataract patients with extremely long AL compared to traditional formulas. Based on the current limited clinical studies, Hill-RBF and Kane formulas seem to be a better choice for eyes with extremely long AL.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CataractCataract ExtractionLenses, IntraocularHumansEyeDatabases, Factual

Autor:innen und Institutionen

  • Nanchong Central Hospital, The Second Clinical College, North Sichuan Medical College, Nanchong, China.
  • Department of Ophthalmology of Affiliated Hospital, North Sichuan Medical College, Nanchong, China.

ORCID-Profile: Xiaoyu Li, Xuan Liao

Förderung

  • Project of the National Natural Science Foundation of Sichuan Provincial Department of Science and Technology

Zitieren

APA

Li, X., Wang, X., & Liao, X. (2024). How to choose the intraocular lens power calculation formulas in eyes with extremely long axial length? A systematic review and meta-analysis. PLOS ONE, 19(1), e0296771. https://doi.org/10.1371/journal.pone.0296771

Vancouver

Li X, Wang X, Liao X. How to choose the intraocular lens power calculation formulas in eyes with extremely long axial length? A systematic review and meta-analysis. PLOS ONE. 2024;19(1):e0296771. doi:10.1371/journal.pone.0296771

BibTeX
@article{Li2024,
  author = {Li, Xiaoyu and Wang, Xiaodong and Liao, Xuan},
  title = {How to choose the intraocular lens power calculation formulas in eyes with extremely long axial length? A systematic review and meta-analysis},
  journal = {PLOS ONE},
  year = {2024},
  volume = {19},
  number = {1},
  pages = {e0296771},
  doi = {10.1371/journal.pone.0296771}
}
Kostenlos starten →