Clinical usability of 3D gradient-echo-based ultrashort echo time imaging: Is it enough to facilitate diagnostic decision in real-world practice?
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0296696 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von So Hyeon Bak und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Lung Neoplasms, Tomography, X-Ray Computed, Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and ICT, South Korea.
Abstract (Originalsprache)
Background
With recent advances in magnetic resonance imaging (MRI) technology, the practical role of lung MRI is expanding despite the inherent challenges of the thorax. The purpose of our study was to evaluate the current status of the concurrent dephasing and excitation (CODE) ultrashort echo-time sequence and the T 1 -weighted volumetric interpolated breath-hold examination (VIBE) sequence in the evaluation of thoracic disease by comparing it with the gold standard computed tomography (CT).
Methods
Twenty-four patients with lung cancer and mediastinal masses underwent both CT and MRI including T 1 -weighted VIBE and CODE. For CODE images, data were acquired in free breathing and end-expiratory images were reconstructed using retrospective respiratory gating. All images were evaluated through qualitative and quantitative approaches regarding various anatomical structures and lesions (nodule, mediastinal mass, emphysema, reticulation, honeycombing, bronchiectasis, pleural plaque and lymphadenopathy) inside the thorax in terms of diagnostic performance in making specific decisions.
Results
Depiction of the lung parenchyma, mediastinal and pleural lesion was not significant different among the three modalities ( p > 0.05). Intra-tumoral and peritumoral features of lung nodules were not significant different in the CT, VIBE or CODE images ( p > 0.05). However, VIBE and CODE had significantly lower image quality and poorer depiction of airway, great vessels, and emphysema compared to CT ( p < 0.05). Image quality of central airways and depiction of bronchi were significantly better in CODE than in VIBE ( p < 0.001 and p = 0.005). In contrast, the depiction of the vasculature was better for VIBE than CODE images ( p = 0.003). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were significant greater in VIBE than CODE except for SNR lung and SNR nodule ( p < 0.05).
Conclusions
Our study showed the potential of CODE and VIBE sequences in the evaluation of localized thoracic abnormalities including solid pulmonary nodules.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
- Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea.
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.
- Department of Health Sciences and Technology, Samsung Advanced Institute for Health Sciences & Technology (SAIHST), Sungkyunkwan University, Seoul, Korea.
ORCID-Profile: Jong Hee Kim, Ho Yun Lee
Förderung
- Ministry of Science and ICT, South Korea
Zitieren
APA
Bak, S. H., Park, J., Lee, S., Kim, J. H., Lee, H. Y., & Park, J. Y. (2024). Clinical usability of 3D gradient-echo-based ultrashort echo time imaging: Is it enough to facilitate diagnostic decision in real-world practice?. PLOS ONE. https://doi.org/10.1371/journal.pone.0296696
Vancouver
Bak SH, Park J, Lee S, Kim JH, Lee HY, Park JY. Clinical usability of 3D gradient-echo-based ultrashort echo time imaging: Is it enough to facilitate diagnostic decision in real-world practice?. PLOS ONE. 2024. doi:10.1371/journal.pone.0296696
BibTeX
@article{Bak2024,
author = {Bak, So Hyeon and Park, Jinil and Lee, Seokwon and Kim, Jong Hee and Lee, Ho Yun and Park, Jang-Yeon},
title = {Clinical usability of 3D gradient-echo-based ultrashort echo time imaging: Is it enough to facilitate diagnostic decision in real-world practice?},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0296696}
}
EUVIMED