EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Speed and efficiency: evaluating pulmonary nodule detection with AI-enhanced 3D gradient echo imaging

Sebastian Ziegelmayer, Alexander W Marka, Maximilian Strenzke, Tristan Lemke, Hannah Rosenkranz, Bernadette Scherer, Thomas Huber, Kilian Weiss, Marcus R Makowski, Dimitrios C Karampinos, Markus Graf, Joshua Gawlitza

European Radiology · 2024

DOI: 10.1007/s00330-024-11027-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Radiology, 2024. Verfasst von Sebastian Ziegelmayer und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany. Hauptthemen laut MEDLINE: Lung Neoplasms, Magnetic Resonance Imaging, Imaging, Three-Dimensional, Solitary Pulmonary Nodule. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Evaluating the diagnostic feasibility of accelerated pulmonary MR imaging for detection and characterisation of pulmonary nodules with artificial intelligence-aided compressed sensing. Materials and methods In this prospective trial, patients with benign and malignant lung nodules admitted between December 2021 and December 2022 underwent chest CT and pulmonary MRI. Pulmonary MRI used a respiratory-gated 3D gradient echo sequence, accelerated with a combination of parallel imaging, compressed sensing, and deep learning image reconstruction with three different acceleration factors (CS-AI-7, CS-AI-10, and CS-AI-15). Two readers evaluated image quality (5-point Likert scale), nodule detection and characterisation (size and morphology) of all sequences compared to CT in a blinded setting. Reader agreement was determined using the intraclass correlation coefficient (ICC).

Results

Thirty-seven patients with 64 pulmonary nodules (solid n = 57 [3–107 mm] part-solid n = 6 [ground glass/solid 8 mm/4–28 mm/16 mm] ground glass nodule n = 1 [20 mm]) were analysed. Nominal scan times were CS-AI-7 3:53 min; CS-AI-10 2:34 min; CS-AI-15 1:50 min. CS-AI-7 showed higher image quality, while quality remained diagnostic even for CS-AI-15. Detection rates of pulmonary nodules were 100%, 98.4%, and 96.8% for CS-AI factors 7, 10, and 15, respectively. Nodule morphology was best at the lowest acceleration and was inferior to CT in only 5% of cases, compared to 10% for CS-AI-10 and 23% for CS-AI-15. The nodule size was comparable for all sequences and deviated on average < 1 mm from the CT size.

Conclusion

The combination of compressed sensing and AI enables a substantial reduction in the scan time of lung MRI while maintaining a high detection rate of pulmonary nodules. Clinical relevance statement Incorporating compressed sensing and AI in pulmonary MRI achieves significant time savings without compromising nodule detection or characteristics. This advancement holds clinical promise, enhancing efficiency in lung cancer screening without sacrificing diagnostic quality. Key Points Lung cancer screening by MRI may be possible but would benefit from scan time optimisation . Significant scan time reduction, high detection rates, and preserved nodule characteristics were achieved across different acceleration factors . Integrating compressed sensing and AI in pulmonary MRI offers efficient lung cancer screening without compromising diagnostic quality.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lung NeoplasmsMagnetic Resonance ImagingImaging, Three-DimensionalSolitary Pulmonary NoduleMultiple Pulmonary NodulesArtificial IntelligenceHumansMaleFemaleMiddle AgedProspective StudiesAgedTomography, X-Ray ComputedFeasibility StudiesAdult

Stichwörter der Autor:innen

Multiple pulmonary nodulesComputed tomographyLungMagnetic resonance images

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany. alexander.marka@tum.de.
  • Philips GmbH Market DACH, Hamburg, Germany.

Zitieren

APA

Ziegelmayer, S., Marka, A. W., Strenzke, M., Lemke, T., Rosenkranz, H., Scherer, B., Huber, T., Weiss, K., Makowski, M. R., Karampinos, D. C., Graf, M., & Gawlitza, J. (2024). Speed and efficiency: evaluating pulmonary nodule detection with AI-enhanced 3D gradient echo imaging. European Radiology. https://doi.org/10.1007/s00330-024-11027-5

Vancouver

Ziegelmayer S, Marka AW, Strenzke M, Lemke T, Rosenkranz H, Scherer B, et al. Speed and efficiency: evaluating pulmonary nodule detection with AI-enhanced 3D gradient echo imaging. European Radiology. 2024. doi:10.1007/s00330-024-11027-5

BibTeX
@article{Ziegelmayer2024,
  author = {Ziegelmayer, Sebastian and Marka, Alexander W and Strenzke, Maximilian and Lemke, Tristan and Rosenkranz, Hannah and Scherer, Bernadette and Huber, Thomas and Weiss, Kilian and Makowski, Marcus R and Karampinos, Dimitrios C and Graf, Markus and Gawlitza, Joshua},
  title = {Speed and efficiency: evaluating pulmonary nodule detection with AI-enhanced 3D gradient echo imaging},
  journal = {European Radiology},
  year = {2024},
  doi = {10.1007/s00330-024-11027-5}
}
Kostenlos starten →