Measurement properties of cervical joint position error in people with and without chronic neck pain
PLOS ONE · 12.10.2023 · 18 (10) · e0292798
DOI: 10.1371/journal.pone.0292798 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 12.10.2023. Verfasst von Ahmad AlDahas und 3 weiteren Autor:innen. Beteiligte Einrichtung: Centre of Precision Rehabilitation for Spinal Pain (CPR Spine), School of Sport, Exercise and Rehabilitation Sciences, College of Life and Environmen…. Hauptthemen laut MEDLINE: Neck Pain, Chronic Pain. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
People with chronic neck pain (CNP) often present with impaired neck proprioception. The most widely used clinical test for assessing neck proprioception is cervical joint position sense which measures joint position error (JPE). This clinical test is typically performed using a laser pointer to examine the accuracy of returning to a neutral head position (NHP) or target head position (THP) following active neck movements. The aim of this study was to determine the measurement properties of JPE using a laser pointer when tested in people with and without CNP under a variety of different testing conditions (i.e., different movement directions, sitting versus standing, NHP versus THP).
Methods
Forty-three participants (23 asymptomatic and 20 with CNP) underwent neck proprioception testing, returning to a NHP and THP in both sitting and standing positions (six trials for each test). A laser pointer was secured on the participant’s forehead and inertial measurement unit (IMU) sensors were placed beneath the laser pointer and at the level of the spinous process of the seventh cervical vertebra. Both the absolute and the constant JPE were assessed.
Findings
For the asymptomatic participants, good reliability (ICC: 0.79) was found only for right rotation of the THP task in sitting. In standing, good reliability (ICC: 0.77) was only found in flexion for the THP task. In standing, good reliability (ICC: 0.77) was only found for right rotation of the THP for the absolute JPE and left rotation (ICC: 0.85) for the constant error of the NHP task. In those with CNP, when tested in sitting, good reliability was found for flexion (ICC: 0.8) for the absolute JPE and good reliability (ICC range: 0.8–0.84) was found for flexion, extension, and right rotation for the constant JPE. In standing, good reliability (ICC range: 0.81–0.88) was found for flexion, and rotation for the absolute JPE. The constant JPE showed good reliability (ICC: 0.85) for right rotation and excellent reliability (ICC: 0.93) for flexion. Validity was weak to strong (r range: 0.26–0.83) and moderate to very strong (r range: 0.47–0.93) for absolute and constant error respectively, when tested in sitting. In standing, the validity was weak to very strong (0.38–0.96) for the absolute JPE and moderate to very strong (r range: 0.54–0.92) for the constant JPE.
Conclusion
The reliability of the measure of JPE when tested in sitting and standing in both groups showed good reliability, but not for all movements. The results of the current study also showed that the laser pointer correlated well with the Noraxon IMUs, but not for all movements. The results of the current study support the use of the JPE using a laser pointer in clinical and research settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Centre of Precision Rehabilitation for Spinal Pain (CPR Spine), School of Sport, Exercise and Rehabilitation Sciences, College of Life and Environmental Sciences, University of Birmingham, Birmingham, United Kingdom.
- Department of Physical Therapy, Al-Sabah Medical Hospital, Ministry of Public Health, Kuwait.
ORCID-Profile: Ahmad AlDahas, Deborah Falla
Zitieren
APA
AlDahas, A., Devecchi, V., Deane, J. A., & Falla, D. (2023). Measurement properties of cervical joint position error in people with and without chronic neck pain. PLOS ONE, 18(10), e0292798. https://doi.org/10.1371/journal.pone.0292798
Vancouver
AlDahas A, Devecchi V, Deane JA, Falla D. Measurement properties of cervical joint position error in people with and without chronic neck pain. PLOS ONE. 2023;18(10):e0292798. doi:10.1371/journal.pone.0292798
BibTeX
@article{AlDahas2023,
author = {AlDahas, Ahmad and Devecchi, Valter and Deane, Janet A and Falla, Deborah},
title = {Measurement properties of cervical joint position error in people with and without chronic neck pain},
journal = {PLOS ONE},
year = {2023},
volume = {18},
number = {10},
pages = {e0292798},
doi = {10.1371/journal.pone.0292798}
}
EUVIMED