EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cervical Sensorimotor Function Tests Using a VR Headset—An Evaluation of Concurrent Validity

Karin Forsberg iD, Johan Jirlén, Inger Jacobson, Ulrik Röijezon iD

Sensors · 07.09.2024 · 24 (17) · 5811

DOI: 10.3390/s24175811 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 07.09.2024. Verfasst von Karin Forsberg und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health, Education, and Technology, Luleå University of Technology, 97187 Luleå, Sweden. Hauptthemen laut MEDLINE: Neck Pain, Reaction Time. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: VINNOVA was partly funding this research., VINNOVA.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sensorimotor disturbances such as disturbed cervical joint position sense (JPS) and reduced reaction time and velocity in fast cervical movements have been demonstrated in people with neck pain. While these sensorimotor functions have been assessed mainly in movement science laboratories, new sensor technology enables objective assessments in the clinic. The aim was to investigate concurrent validity of a VR-based JPS test and a new cervical reaction acuity (CRA) test. Twenty participants, thirteen asymptomatic and seven with neck pain, participated in this cross-sectional study. The JPS test, including outcome measures of absolute error (AE), constant error (CE), and variable error (VE), and the CRA test, including outcome measures of reaction time and maximum velocity, were performed using a VR headset and compared to a gold standard optical motion capture system. The mean bias (assessed with the Bland–Altman method) between VR and the gold standard system ranged from 0.0° to 2.4° for the JPS test variables. For the CRA test, reaction times demonstrated a mean bias of −19.9 milliseconds (ms), and maximum velocity a mean bias of −6.5 degrees per seconds (°/s). The intraclass correlation coefficients (ICCs) between VR and gold standard were good to excellent (ICC 0.835–0.998) for the JPS test, and excellent (ICC 0.931–0.954) for reaction time and maximum velocity for the CRA test. The results show acceptable concurrent validity for the VR technology for assessment of JPS and CRA. A slightly larger bias was observed in JPS left rotation which should be considered in future research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Neck PainReaction TimeHumansFemaleAdultMaleCross-Sectional StudiesCervical VertebraeYoung AdultVirtual RealityRange of Motion, ArticularProprioceptionMovementNeckMiddle Aged

Stichwörter der Autor:innen

VRagreementcorrelationjoint position senseneck painreaction timesensorimotorvelocityvirtual reality

Autor:innen und Institutionen

  • Department of Health, Education, and Technology, Luleå University of Technology, 97187 Luleå, Sweden.

ORCID-Profile: Karin Forsberg, Ulrik Röijezon

Förderung

  • VINNOVA was partly funding this research.
  • VINNOVA

Zitieren

APA

Forsberg, K., Jirlén, J., Jacobson, I., & Röijezon, U. (2024). Cervical Sensorimotor Function Tests Using a VR Headset—An Evaluation of Concurrent Validity. Sensors, 24(17), 5811. https://doi.org/10.3390/s24175811

Vancouver

Forsberg K, Jirlén J, Jacobson I, Röijezon U. Cervical Sensorimotor Function Tests Using a VR Headset—An Evaluation of Concurrent Validity. Sensors. 2024;24(17):5811. doi:10.3390/s24175811

BibTeX
@article{Forsberg2024,
  author = {Forsberg, Karin and Jirlén, Johan and Jacobson, Inger and Röijezon, Ulrik},
  title = {Cervical Sensorimotor Function Tests Using a VR Headset—An Evaluation of Concurrent Validity},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {17},
  pages = {5811},
  doi = {10.3390/s24175811}
}